- Article no.:
 
- DK 7979713
 
- Design
 
- 16 A / three-phase 
 
- Product description
 
- Autonomous energy metering unit (including differential current monitoring) in a 1 U/19" form factor. The unit is incorporated into the supply lead to the equipment, a PDU basic or a modular PDU without measurement function. All key electrical characteristics are logged in the same way as with a PDU metered. Additionally, the measurement module features an integral differential current measurement (type B) for fault current monitoring of the connected equipment. Consumption data is conveniently retrieved via a network interface or locally via a TFT display. Additionally, all the PDU metered interfaces, e.g. for connecting external sensors and smart handle systems, are available. 
 
- Benefits
 
- The ideal solution for upgrading existing installations which lack modern measurement functions 
 
- Includes differential current measurement/fault current monitoring 
 
- Extensive measuring functions (as for PDU metered) 
 
- Versions with connection cable and CEE connectors, ready to use immediately 
 
- Fast upgrade, installation only requires a brief interruption to operation 
 
- Compact 1 U 482.6 mm (19˝) enclosure with pre-assembled connection cables 
 
- High degree of measurement accuracy (typically ±1%) 
 
- Energy-efficient design, minimal inherent power consumption 
 
- Acoustic alarm may be set if certain limits are exceeded (such as fault currents) 
 
- Integral GbE interface with web server for autonomous operation without other components 
 
- Material
 
- Extruded aluminium section, anodised 
 
- General colour
 
- RAL 9005 
 
- Colour
 
- RAL 9005 
 
- Options
 
- CMC III CAN bus sensors may be connected for ambient monitoring, max. 16 sensors 
 
- Power consumption
 
- 11 kW 
 
- Type of electrical connection
 
- CEE connector/coupling 
 
- Phases per infeed
 
- 3~ 
 
- Rated current (max.)
 
- 16 A 
 
- Directives
 
- Low Voltage Directive 2014/35/EU 
 
- EMC Directive 2014/30/EU 
 
- Standards
 
- EN 62368-1 
 
- EN 61000-4 
 
- EN 61000-6 
 
- EN 55 022 
 
- Dimensions
 
- Width: 450 mm
Height: 144 mm
Depth: 44 mm  
- Interfaces
 
- Fully redundant Ethernet interface 10/100/1000 Mbit/s (2x RJ45, 1x with PoE) 
 
- USB 2.0 port (USB-A) for mass configuration, firmware updates & data logging 
 
- CAN bus interface (RJ 45) for a maximum of 16 ambient sensors 
 
- Serial interface RS232 (RJ12) for LTE unit, scripting, CLI 
 
- Use of own certificates/TLS 1.2 
 
- E-mail forwarding in case of alarm (SMTP) 
 
- User administration including rights management 
 
- LDAP(S)/Radius/Active Directory connection 
 
- Syslog server connection (max. 2 servers) 
 
- Input cable connection (type/length)
 
- H05VV-F5G2.5, 2 m 
 
- Output cable connection (type/length)
 
- H05VV-F5G2.5, 1,2 m 
 
- Packs of
 
- 1 pc(s). 
 
- Net weight
 
- 3.2 kg
 
- Gross weight
 
- 3.7 kg
 
- Customs tariff number
 
- 85369095 
 
- EAN
 
- 4028177948501 
 
- ETIM 9
 
- EC002762 
 
- ECLASS 8.0
 
- 27060402 
 
- Product description
 
- 
DK RCM measuring module – inline meter, autonomous energy acquisition unit, for PDU basic or modular PDU without measuring functions, 1 U, 482.6 mm (19"), incl. sensor interface, rated power: 11.0 kW, rated current: 16 A, 3~, connection type: CEE connector/coupling, connection cable / length: H05VV F5G2.5 / 1 m, extruded aluminium section, anodised, RAL 9005