This item will be discontinued on: Jan 31, 2021
This item is being replaced by:
3185330
Outdoor cooling unit for CS Toptec
Article number: CS 9776.550
Useful cooling output/heater 1,400 W/400 W, temperature control via e-Comfort controller. For mounting on the CS Toptec in 3 positions: External, partial internal and full internal mounting.
- Article number:
- CS 9776.550
- Product description
- Temperature control via e-Comfort controller. The cooling unit may be attached to the enclosure in 3 positions (external, partial internal and full internal mounting).
- Benefits
- May be linked to the IoT interface via Blue e IoT adaptor for cooling units from 500 W cooling output with e-Comfort controller
- Material
- Aluminium
- Surface finish
- Powder-coated
Pure polyester - Colour
- RAL 7035
- Supply includes
- Fully wired ready for connection (plug-in terminal strip)
Mounting frame for universal attachment to outdoor enclosures for external, partial internal and full internal mounting. - IP protection category to IEC 60 529
- External circuit IP 34
- Internal circuit IP 55
- Total cooling output to DIN EN 14511
- Cooling output L35 L35/50 Hz: 1.4 kW
Cooling output L35 L35/60 Hz: 1.53 kW
Cooling output L35 L50/50 Hz: 1.06 kW
Cooling output L35 L50/60 Hz: 1.1 kW - Heater output
- 400 W
- Rated operating voltage
- 230 V, 1~, 50 Hz/60 Hz
- Start-up current max.
- At 50 Hz: 34 A
At 60 Hz: 32 A - Air throughput (unimpeded air flow)
- External circuit with 50 Hz: 1,000 m³/h
External circuit with 60 Hz: 1,090 m³/h
Internal circuit at 50 Hz: 880 m³/h
Internal circuit at 60 Hz: 950 m³/h - Rated current max.
- At 50 Hz: 6 A
At 60 Hz: 6.8 A - Temperature control
- e-Comfort controller (factory setting +35 °C)
- Operating temperature range
- -33 °C...55 °C
- Setting range
- 20 °C...55 °C
- Refrigerant/cooling medium
- Refrigerant: R134a
Quantity: 0.9 kg
Global Warming Potential (GWP): 1,430
CO₂ equivalent (CO₂e): 1.3 t - Power consumption Pel
- Power consumption L35 L35/50 Hz: 0.96 kW
Power consumption L35 L35/60 Hz: 1.17 kW
Power consumption L35 L50/50 Hz: 1.13 kW
Power consumption L35 L50/60 Hz: 1.25 kW - Permissible operating pressure (p. max.)
- 28 bar
- Dimensions
- Width: 500 mm
Height: 1,000 mm
Depth: 274 mm - Enclosure dimensions including sealing frame and designer cover
- Width: 552 mm
Height: 1,052 mm
Depth: 274 mm - Energy efficiency ratio (EER) 50/60 Hz L35 L35
- Refrigeration factor L35 L35 (EER) 50 Hz: 1.46
Refrigeration factor L35 L35 (EER) 60 Hz: 1.31 - Pre-fuse
- Miniature circuit-breaker/fuse: 10 A
- To fit
- Enclosure type: CS Toptec
Width: ≥ 800 mm
Height: ≥ 1,200 mm - Installation type
- Universal installation (external mounting, partial internal mounting, full internal mounting)
- Packs of
- 1 pc(s).
- Weight/pack
- 45 kg
- Customs tariff number
- 84158200
- EAN
- 4028177463110
- ETIM 7.0
- EC000855
- ECLASS 8.0
- 27180704
Cooling unit 1600 W for outdoor use in the temperature
range from -33° to +55°C
For universal installation, partial internal mounting
or external mounting on side panels, rear panels or
doors of outdoor enclosures, minimum enclosure
dimensions WxH 800 x 1200 mm.
With microcontroller for temperature control and
monitoring, diagnostics and evaluation of error
messages of the cooling unit. The protection category
of IP 55 for the enclosure is retained due to the
separation of internal circuit and external circuit.
Installation: Universal installation, the unit can
optionally be mounted on the special mounting frame
with all-round seal on the inside, on the outside or
partially internal. A later modification of the
installation type is easily possible.
Enclosure dimensions (mm) WxHxD 500 x 1000 x 235 mm
Minimum enclosure dimension mm WxH or DxH: 800 x 1200
Useful cooling output to EN 814:
L35 L35 1600/1750 W
L 35 L 50 1200/1250 W
Coolant: R 134a
Rated operating voltage: 230 V AC /50/60 Hz
With integral heater, 400 W
Type of connection: Female multi-point connector
9-pole. Temperature control via microcontroller.
Temperature range of environment -33°C to +55°C
Material (enclosure): Aluminium
Surface finish: Spray finished in RAL 7035
Protection category (internal circuit to external
circuit):
IP 55 to EN 60529/10.91
Model:
Rittal
Type:
Toptec cooling unit CS 9776.550 or equivalent
range from -33° to +55°C
For universal installation, partial internal mounting
or external mounting on side panels, rear panels or
doors of outdoor enclosures, minimum enclosure
dimensions WxH 800 x 1200 mm.
With microcontroller for temperature control and
monitoring, diagnostics and evaluation of error
messages of the cooling unit. The protection category
of IP 55 for the enclosure is retained due to the
separation of internal circuit and external circuit.
Installation: Universal installation, the unit can
optionally be mounted on the special mounting frame
with all-round seal on the inside, on the outside or
partially internal. A later modification of the
installation type is easily possible.
Enclosure dimensions (mm) WxHxD 500 x 1000 x 235 mm
Minimum enclosure dimension mm WxH or DxH: 800 x 1200
Useful cooling output to EN 814:
L35 L35 1600/1750 W
L 35 L 50 1200/1250 W
Coolant: R 134a
Rated operating voltage: 230 V AC /50/60 Hz
With integral heater, 400 W
Type of connection: Female multi-point connector
9-pole. Temperature control via microcontroller.
Temperature range of environment -33°C to +55°C
Material (enclosure): Aluminium
Surface finish: Spray finished in RAL 7035
Protection category (internal circuit to external
circuit):
IP 55 to EN 60529/10.91
Model:
Rittal
Type:
Toptec cooling unit CS 9776.550 or equivalent