Liquid Cooling Package LCP Inline CW, LCP Inline CWG

Article number: SK 3313.570

Bayed climate control designed for siting within a bayed enclosure suite. The hot air is extracted at the rear of the unit, cooled and then expelled forwards to the cold aisle.

Article number:
SK 3313.570
Design
CWG
Benefits
Maximum energy efficiency due to EC fan technology and IT-based control
Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans
Optimum adaptability due to dynamic, continuous control of the cold water volume flow
By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs
Targeted cooling output due to modular fan units
Fan modules configurable as n+1 redundancy
Standard 3-phase connection for electrical redundancy
With redundant temperature sensor integrated at the air end as standard
The separation of cooling and enclosure prevents the ingress of water into the server enclosure
A footprint of max. 0.36 m² for all cooling services
Improved heat recovery, thanks to high water return temperatures when using LCP CW glycol variants, for example in combination with a heat pump
Optimum access for maintenance and servicing from the front and rear
Tool-free replacement of the fan modules
Function principle
The hot air is drawn in from the room or hot aisle at the rear of the device and expelled at the front into the cold aisle after cooling. With this product, a raised floor is not necessary.
Material
Sheet steel, spray-finished
Colour
RAL 7035
Options
Direct connection of additional CMC III sensors is supported
Racks 2200 mm high
Design
Suite cooling
Monitoring
Monitoring of all system-relevant parameters such as server air intake temperature, server waste air temperature, water inlet/return temperature, water flow, cooling output, fan speed, leakage
Direct connection of the unit via SNMP over Ethernet
Integration into RiZone
Total cooling output/Number of fan modules
38 kW/4
40 kW/5
44 kW/6
Air throughput (unimpeded air flow)
At 50 Hz: 4,800 m³/h
Number of fans
4
Dimensions
Width: 300 mm
Height: 2,000 mm
Depth: 1,200 mm
To fit enclosure type
VX IT
Installation in bayed enclosure suite
Set forward
Rated operating voltage
230 V, 1~, 50 Hz/60 Hz
400 V, 3~, 50 Hz/60 Hz
Max. cooling output
35 kW
Type of electrical connection
Connector
Duty cycle
100 %
Cooling medium
Water/glycol
EC fan
Yes
Fans may be exchanged with the system operational
Yes
Temperature control
Linear fan control
Two-way control valve
Water connections
DN 40 (G 1½" external thread)
Permissible operating pressure (p. max.)
10 bar
Water inlet temperature
15 °C
Protection category to IEC 60 529
IP 20
Optimized condensate management even at low water flow temperatures
Yes
Packs of
1 pc(s).
Weight/pack
280 kg
Customs tariff number
84158200
EAN
4028177953956
ETIM 7.0
EC002515
ECLASS 8.0
27180712
Product description
SK LCP Inline CW/glycol, 35 kW, RAL 7035, WHD: 300 x 2000 x 1200 mm
Declarations
Declaration of conformity
Documentation
Instructions
Data sheets
Visio Shapes
Software
Software