NH fuse-switch-disconnectors, size 000 for mounting plate assembly
Model No. 3431.000
Product Lifecycle
Active
+ Product description
Material: |
Fibreglass-reinforced polyamide Fire protection corresponding to UL 94 Contact tracks: Silver-plated hard copper |
---|---|
Colour: |
Chassis: RAL 9011 Cover: RAL 7035 |
Clamping area for laminated copper bars: |
Width: 10 mm Height: 10 mm |
for mounting plate assembly: | yes |
Cable outlet: | Top/bottom |
Type of electrical connection: | Box terminal |
Rated operating current max.: | 100 A |
For NH size: | 000 |
Test specification: |
IEC/DIN EN 60 947-3 DIN EN 60 269-2 (fuse inserts) |
Dimensions: |
Width: 89 mm Height: 141.5 mm |
Connection for round conductor cross-sections: | 1.5 ‐ 50 mm² |
Rated operating voltage: | 690 V, 3~ |
Number of poles: | 3-pole |
Packs of: | 1 pc(s). |
Weight/pack: | 0.451 kg |
Copper weight (kg per piece): | 0.15 |
Customs tariff number: | 85369095 |
EAN: | 4028177042391 |
ETIM 7.0: | EC001040 |
ECLASS 8.0: | 27371401 |
Product description: | SV NH fuse-switch disconnector, size 000, 100 A, 690 V, 3-pole, box terminal, for mounting plate assembly |
+ Approvals
Approvals: |
CQC-CCC:
EN, ZH
|
---|---|
Certificates: |
EAC:
RU
|
Declerations: |
Declaration of conformity:
DE, EN
|
+ Add accessories
+ Tender texts
NH fuse-switch-disonnector
for mounting plate assembly
Monitoring of lid position is possible.
Type: size 000
Rated operating current: 100 A
160 A for 95 mm2
Connection cross section
95 mm2 connection piece available on request
Rated operating voltage: 690 V AC
Rated insulation voltage: 690 V AC
Rated surge voltage resistance: 4 kV
Insulation group to VDE 0110: C
Conditional rated short-circuit current
when protected with fuses: 80 kA for fuses 100 A
20 kA for fuses 160 A
Rated making capacity with fuse: =/1 of
fuse inserts to VDE 0636 part 21
Rated breaking capacity to
VDE 0660 part 107/IEC 60 947-3: AC 22B for 400 V~
Mechanical life: > 1000 (switching cycles)
Permissible ambient temperature: - 25 °C to +55 °C
Fire protection corresponding to UL 94-V0
Pvmax./fuse insert: 7.5 W
Cable outlet: top / bottom
Type of connection:
Terminal up to 50 mm2
Tightening torque
Terminal screw: 3 Nm
without fuse monitoring
Material
Isolator lid: fibreglass-reinforced polyamide
Contact hazard protection:
fibreglass-reinforced polyamide
Isolator chassis: fibreglass-reinforced polyamide
Contact tracks: silver-plated hard copper
for mounting plate assembly
Monitoring of lid position is possible.
Type: size 000
Rated operating current: 100 A
160 A for 95 mm2
Connection cross section
95 mm2 connection piece available on request
Rated operating voltage: 690 V AC
Rated insulation voltage: 690 V AC
Rated surge voltage resistance: 4 kV
Insulation group to VDE 0110: C
Conditional rated short-circuit current
when protected with fuses: 80 kA for fuses 100 A
20 kA for fuses 160 A
Rated making capacity with fuse: =/1 of
fuse inserts to VDE 0636 part 21
Rated breaking capacity to
VDE 0660 part 107/IEC 60 947-3: AC 22B for 400 V~
Mechanical life: > 1000 (switching cycles)
Permissible ambient temperature: - 25 °C to +55 °C
Fire protection corresponding to UL 94-V0
Pvmax./fuse insert: 7.5 W
Cable outlet: top / bottom
Type of connection:
Terminal up to 50 mm2
Tightening torque
Terminal screw: 3 Nm
without fuse monitoring
Material
Isolator lid: fibreglass-reinforced polyamide
Contact hazard protection:
fibreglass-reinforced polyamide
Isolator chassis: fibreglass-reinforced polyamide
Contact tracks: silver-plated hard copper