TopTherm wall-mounted cooling unit Blue e, UL Type 3R/4 0.5 - 2.5 kW

Model No. 3303.508

  Product Lifecycle  
Active
  • TopTherm wall-mounted cooling unit Blue e, UL Type 3R/4 0.5 - 2.5 kW
  • TopTherm wall-mounted cooling unit Blue e, UL Type 3R/4 0.5 - 2.5 kW
    Product details

    Energy-efficient Blue e wall-mounted cooling units in output categories 500 W to 2,500 W with integral e-Comfort controller and electric condensate evaporation (from 1000 W) as standard, protection category UL Type 3R/4, 12.

    + Product description

    Product description: Energy-efficient Blue e wall-mounted cooling units with integral e-Comfort controller and electric condensate evaporation as standard. Protection category UL Type 3R/4, 12.
    Benefits: Suitable for outdoor siting
    Blue e technology
    May be linked to the IoT interface via Blue e IoT adaptor for cooling units from 500 W cooling output with e-Comfort controller
    Material: Sheet steel
    Colour: RAL 7035
    Supply includes: Condenser with hydrophobic RiNano coating
    Fully wired ready for connection (plug-in terminal strip)
    Drilling template
    Assembly parts
    Total cooling output to DIN EN 14511: Cooling output L35 L35/50 Hz: 0.46 kW
    Cooling output L35 L35/60 Hz: 0.55 kW
    Cooling output L35 L50/50 Hz: 0.27 kW
    Cooling output L35 L50/60 Hz: 0.32 kW
    Rated operating voltage: 230 V, 1~, 50 Hz/60 Hz
    Rated current max.: At 50 Hz: 2.6 A
    At 60 Hz: 2.6 A
    Start-up current max.: At 50 Hz: 5.1 A
    At 60 Hz: 6.4 A
    Air throughput (unimpeded air flow): External circuit: 315 m³/h
    Internal circuit: 265 m³/h
    Energy efficiency ratio (EER) 50/60 Hz L35 L35: Refrigeration factor L35 L35 (EER) 50 Hz: 1.31
    Refrigeration factor L35 L35 (EER) 60 Hz: 1.3
    Design: wall-mounted
    Dimensions: Width: 285 mm
    Height: 620 mm
    Depth: 298 mm
    Protection category to IEC 60 529: External circuit IP 34
    Internal circuit IP 56
    Protection category NEMA: UL Type 3R
    UL Type 4
    UL Type 12
    Refrigerant/cooling medium: Refrigerant: R134a
    Quantity: 0.17 kg
    Global Warming Potential (GWP): 1,430
    CO₂ equivalent (CO₂e): 0.24 t
    Temperature control: e-Comfort controller (factory setting +35 °C)
    Operating temperature range: -20 °C...50 °C
    Operating temperature: Compressor cooling mode from +10 °C ambient temperature. Only the internal fan is active in the temperature range -20 °C to +10 °C.
    Storage temperature range: -40 °C...70 °C
    Setting range: 20 °C...50 °C
    Power consumption Pel: Power consumption L35 L35/50 Hz: 0.35 kW
    Power consumption L35 L35/60 Hz: 0.42 kW
    Power consumption L35 L50/50 Hz: 0.4 kW
    Power consumption L35 L50/60 Hz: 0.48 kW
    Permissible operating pressure (p. max.): 28 bar
    Pre-fuse: Miniature circuit-breaker/fuse: 10 A
    Note on Model No.: without integral condensate evaporation
    Packs of: 1 pc(s).
    Weight/pack: 25 kg
    Customs tariff number: 84158200
    EAN: 4028177943674
    ETIM 7.0: EC000855
    ECLASS 8.0: 27180704
    Product description: SK cooling unit Blue e, wall-mounted, UL Type 3R/4,, 0.46 kW, 230 V, 1~, 50/60 Hz,, Sheet steel,, WHD: 285 x 620 x 298 mm,

    + Approvals

    Approvals:
    C-UL: 
    EN
    UL + C-UL (listed): 
    EN
    UL + C-UL - FTTA: 
    EN
    Certificates:
    EAC: 
    RU
    Declerations:
    Declaration of conformity: 
    DE, EN FR
    Declaration of conformity - F-gas regulation: 
    DE, EN
    Declaration of conformity UK: 
    EN

    + Downloads / CAD

    Data Sheets:
    Safety data sheet refrigerant: 
    CS DE EN ES IT JA PL SK
    Technical system catalogue: 
    DE EN JA
    Documentation:
    Instructions: 
    DE EN
    White Paper: 
    DE EN

    + Add accessories

    + Tender texts

    SK 3303.508
    Wall-mounted cooling unit TopTherm Blue e, UL Type 3R/4
    Energy-efficient Blue e wall-mounted cooling units
    with e-Comfort controller integrated as standard,
    and electrical condensate evaporation (from 1000 W),
    hydrophobic RiNano coating on the condenser,
    protection category NEMA 3R/4/12.
    Total cooling output DIN EN 14511:
    L35 L35 at 50/60 Hz: 0,46/0,55 kW
    L35 L50 at 50/60 Hz: 0,27/0,32 kW
    Power consumption:
    L35 L35 at 50/60 Hz: 0,35/0,42 kW
    L35 L50 at 50/60 Hz: 0,4/0,48 kW
    Rated voltage: 230 V, 1~, 50/60 Hz
    Rated current (max.) at 50/60 Hz: 2,6/2,6 A
    Energy efficiency ratio L35 L35
    EER at 50/60 Hz: 1,31/1,3
    Air throughput of fans (unimpeded air flow) internal circuit: 315 m³/h
    Air throughput of fans (unimpeded air flow) external circuit: 265 m³/h
    Dimensions WxHxD [mm]: 285 x 620 x 298 (350 mm with electrical box)
    Refrigerant: R134a
    Refrigerant filling mass: 170 g
    Temperature control: e+ Controller (factory setting +35°C)
    Operating temperature: -20°C to +50°C
    Setting range set value: +20°C to +50°C
    Storage temperature range: -40°C to +70°C
    Protection category to IEC 60 529:
    Internal circuit IP 34
    External circuit IP 56 (interface to enclosure only)
    Protection category Nema:
    UL Type 3R, 4, 12
    Weight: 25 kg
    Material: Sheet steel
    Colour: RAL 7035

     TopTherm wall-mounted cooling unit Blue e, UL Type 3R/4 0.5 - 2.5 kW