TopTherm fan-and-filter units with EC technology

Model No. 3241.500

  Product Lifecycle  
Active
  • TopTherm fan-and-filter units with EC technology
  • TopTherm fan-and-filter units with EC technology Anreih-Systeme TS 8
    Product details

    Energy-efficient version of the RTT fan-and-filter units with EC technology. From 180 m³/h with integral control interface (0-10 V / PWM input and tachosignal output) to regulate and monitor the fan.

    + Product description

    Product description: Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
    Colour: RAL 7035
    Supply includes: Complete unit ready to install, including chopped-fibre filter mat
    Fan: Diagonal, EC motor
    Air throughput, unimpeded airflow (with chopped-fibre filter): At 50 Hz: 225 m³/h
    At 60 Hz: 225 m³/h
    Air throughput, unimpeded airflow (with pleated filter): At 50 Hz: 272 m³/h
    At 60 Hz: 272 m³/h
    Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number): 1 x 3240200: 171 m³/h
    2 x 3240200: 200 m³/h
    Rated operating voltage: 200 V - 240 V, 1~, 50 Hz/60 Hz
    Power consumption Pel: At 50 Hz: 11 W
    At 60 Hz: 11 W
    Rated current max.: At 50 Hz: 0.17 A
    At 60 Hz: 0.15 A
    Dimensions: Width: 255 mm
    Height: 255 mm
    Installation depth: 107 mm
    Mounting cut-out: Cut-out width: 224 mm
    Cut-out height: 224 mm
    IP protection category to IEC 60 529: IP54 with chopped-fibre filter/pleated filter
    IP55 with pleated filter and absorber mat
    IP56 with chopped-fibre filter/pleated filter and hose-proof hood
    Protection category NEMA: Type 12 with chopped-fibre filter/pleated filter
    Type 3, 3R, 4, 4X with chopped-fibre filter/pleated filter and hose-proof hood
    Control interface: yes
    Pre-fuse: Miniature circuit-breaker/fuse: 6 A
    Note: To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
    For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
    Operating temperature range: -25 °C...55 °C
    Storage temperature range: -25 °C...70 °C
    Noise level: At 50 Hz: 52 dB(A)
    At 60 Hz: 52 dB(A)
    Weight/pack: 1,98 kg
    Packs of: 1 pc(s).
    Customs tariff number: 84145915
    EAN: 4028177652026
    ETIM 7.0: EC000320
    ECLASS 8.0: 27180716
    Product description: SK Fan-and-filter unit TopTherm, 225 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 255 x 255 x 25 mm, EC technology

    + Approvals

    Approvals:
    CSA: 
    EN
    UL + C-UL - FTTA: 
    EN
    UR + C-UR (recognized): 
    EN
    Declerations:
    Declaration of conformity: 
    CS DE, EN
    Declaration of conformity UK: 
    EN

    + Downloads / CAD

    Data Sheets:
    Technical details: 
    DE EN
    Technical system catalogue: 
    DE EN JA
    Documentation:
    Instructions: 
    DE EN ES FR IT JA NL SV

    + Add accessories

    + Tender texts

    TopTherm fan-and-filter units with EC technology
    Energy-efficient version of the
    TopTherm fan-and-filter units with diagonal fan technology.
    Fans 3240.500 to 3245.510 may be controlled and monitored.
    The fan may be activated via the control interface
    with tacho signal output integrated as standard,
    and monitoring of the fan speed and function is supported.
    Air troughput (unimpeded air flow): 225 m3/h
    Power consumption 50/60 Hz: 16 / 16 W
    Rated power input 50/60 Hz: 0,17 / 0,17 A
    Rated operating voltage: 200-240 V, 1~, 50/60 Hz
    Diagonal fan: Diagonal, EC motor
    Dimensions [WxH]: 255x255 mm
    Installation depth: 107 mm
    Build depth: 25 mm
    Required mounting cut-out [WxH]: 224x224 mm
    Operating temperature range: -25 °C to 55 °C
    Storage temperature range: -25 °C to 70 °C
    Colour: RAL 7035
    Protection category IP to IEC 60 529:
    IP 54 with fleece filter/pleated filter
    IP 55 with pleated filter and absorber mat
    IP 56 with fleece filter/pleated filter and hose-proof hood
    Protection category NEMA:
    Type 12 with fleece filter/pleated filter
    Type 3, 3R, 4, 4X with fleece filter/pleated filter and hose-proof hood
    Noise level 50/60 Hz: 52 / 52 dB(A)
    Service life 50/60 Hz: 64.000 h
    Weight: 1,98 kg

     TopTherm fan-and-filter units with EC technology