CMC III sensors
Article number: DK 7320.630
Monitor various parameters in enclosures or rooms.
- Article number:
- DK 7320.630
- Design
- Leak sensor
- Product description
- CMC III sensors are used for monitoring the physical environment and can be connected directly to the PU via a CAN bus connection cable RJ45. The sensors may also be linked together to form a bus.
- Benefits
- Fast connection and automatic detection via plug & play
- Power is supplied via the CAN-BUS interface.
- Applications
- Enclosure monitoring in IT, industry and facility management
- Monitoring of enclosures, rooms and containers in the IT environment
- Function principle
- Settings can be made via the CMC III Processing Unit
- The sensor is mounted with the optical element towards the base.
- The sensor monitors the base for liquids (leakage) with an optical sensor.
- Material
- Plastic
Front: Smooth
Enclosure: Textured - Colour
- Enclosure: RAL 7035
- Supply includes
- Sensor
Mounting plate
Assembly parts
Connection cable with connector
Assembly parts - Connection to the CAN bus
- Indirect, via CMC III CAN bus interfaces
- Interfaces
- RJ12
- No. of participating PU compact (max.)
- 4
- No. of participating PU (max.)
- 32
- Measuring technique
- visual
- Dimensions
- Width: 85 mm
Height: 20 mm
Depth: 18 mm - Operating temperature range
- 5 °C...45 °C
- Ambient humidity (non-condensing)
- 5...95 %
- Packs of
- 1 pc(s).
- Weight/pack
- 0.1 kg
- Customs tariff number
- 85319000
- EAN
- 4028177438590
- ETIM 7.0
- EC002627
- ECLASS 8.0
- 27189253
- Declarations
- Declaration of conformity
Leakage sensor
The leakage sensor is equipped with an optical sensor
head. If this sensor head becomes wet with moisture,
it reports a leakage alarm. The sensor head may be
mounted facing the floor.
The sensor contains an ID so that it is automatically
detected and set-up by the CMC-TC system. The
connection cable, supplied loose, should be used for
connection to the sensor unit.
Technical specifications
Monitoring: Visual
Connection: RJ 12 jack, 6-pole
Connection: Length 2m, RJ 12 connector 6/6
on both sides
Temperature application range: + 5°C to + 45°C
Protection category: IP40
The leakage sensor is equipped with an optical sensor
head. If this sensor head becomes wet with moisture,
it reports a leakage alarm. The sensor head may be
mounted facing the floor.
The sensor contains an ID so that it is automatically
detected and set-up by the CMC-TC system. The
connection cable, supplied loose, should be used for
connection to the sensor unit.
Technical specifications
Monitoring: Visual
Connection: RJ 12 jack, 6-pole
Connection: Length 2m, RJ 12 connector 6/6
on both sides
Temperature application range: + 5°C to + 45°C
Protection category: IP40