Fan module for LCP Rack/Inline CW

Model No. 3313.016

  Product Lifecycle  
Active
  • Fan module for LCP Rack/Inline CW
    Product details

    Increased cooling output. Additionally redundancy can be achieved or the electric power consumption can be reduced.

    + Product description

    Design: for LCP Rack/Inline CW
    Product description: To increase the cooling output, individual fan modules may be retro-fitted into the LCPs. Additional integration can also achieve redundancy or reduce the electric power consumption of the LCPs.
    Benefits: May be connected with the system operational
    Tool-free replacement of the fan modules
    Function principle: Installing fan modules in an LCP increases the air throughput and hence the cooling output of the chosen variant. With an adequate cooling output, fan modules may be added to create redundancy. Retro-fitting additional fans over and above the required volumetric air flow allows you to reduce the electrical energy consumption, since the fans then operate at a lower speed. At the same time, the noise level of the unit will be significantly reduced.
    Material: Enclosure: Sheet steel
    Colour: RAL 9005
    Supply includes: 1 fan unit
    EC fan
    Fully wired ready for connection
    Assembly parts
    Power consumption: 500 W
    Speed: 3,780 rpm
    Air throughput (unimpeded air flow): 1,990 m³/h
    Packs of: 1 pc(s).
    Weight/pack: 6.9 kg
    Customs tariff number: 84145915
    EAN: 4028177954458
    ETIM 7.0: EC000320
    ECLASS 8.0: 27180716
    Product description: SK fan module, UL, for LCP Rack/Inline CW, based on VX IT, to increase the cooling capacity, individual fan modules may be retro-fitted into the LCPs. Additional integration can also achieve redundancy or reduce the electric power consumption of the LCP. RAL 9005

    + Downloads / CAD

    + Tender texts

    LCP fan module 3313.016,
    for LCP CW 3313.130/230/250/260/530/540/550/560/570/238/268/548/538/568
    3314.130/230/250/260/530/540/542/550/560/570/238/268/548/538/568

    The fan module is suitable for use with LCP Rack / Inline CW.
    The installation of additional fan modules in an LCP increases the air
    throughput and thus the cooling output of the respective variant.
    If the cooling output is already sufficient, additional fan modules may
    be used to achieve redundancy.
    Furthermore, the electrical power consumption can be reduced by
    retrofitting fans capable of supplying more than the required volumetric
    air flow, because the fans will then operate at a lower speed.
    The noise level of the unit will also be reduced significantly.
    The fans can be replaced in a matter of seconds and without the need for
    tools or specially qualified personnel, also during continued operation

    LCP fan module, supply includes:
    Metal housing with EC fan, ready for connection and with fixing
    materials
    Rated voltage: 200 V-277 V, 1~, N PE, 50/60 Hz
    Max. speed: 3780 rpm
    Max. power consumption: 500 W
    qV (volumetric flow) unimpeded: 1990 m³/h
    Colour: RAL 9005