Chillers for IT cooling

Model No. 3232.701

  Product Lifecycle  
Active
  • Chillers for IT cooling
    Product details

    Especially for cooling IT applications, such as LCP or air/water heat exchangers. Safety-relevant features such as redundant speed-controlled pumps, two compressors or buffer stores.

    + Product description

    Benefits: Indirect free cooling – internal and external
    High-efficiency pumps in the cold water circuit
    Inverter-controlled pumps
    Two high-performance compressors
    Up to 8 chillers may be linked together to form a cascade
    Technical specifications: Compact design with control components in the front and air intake via both side panels, air outlet upwards
    Pressure-sealed system
    Integral bypass
    Applications: Especially for cooling IT applications, such as LCP or CRAC
    Colour: RAL 7035
    Supply includes: Chiller wired ready for connection
    Multilingual documentation
    Functional diagram and wiring plans
    Options: Free cooling may be integrated from 15 kW. Please follow the instructions
    Buffer store for separate siting
    Emergency cooling with mains water infeed
    Rated operating voltage: 400 V, 3~, 50 Hz
    Rated current max.: At 50 Hz: 23 A
    Tank: Material: Steel tank, with 10 mm condensate insulation
    Volume: 48 l
    Cooling output (footnote): Cooling output makes allowance for 35% glycol
    Cooling output TW15 TU35/50 Hz: 15 kW
    Pump pressure: 2.5 bar
    Pump capacity (at 2.5 bar/50 Hz): 60 l/min
    Water connections: G 1½" internal thread
    Operating weight: 448 kg
    Number of cooling circuits: 1
    Monitoring: Monitoring of all system-relevant parameters such as: water inlet, refrigerant and pump parameters and alarms, as well as optional cooling outputs and energy efficiency
    Direct connection of the unit via SNMP/Modbus over Ethernet.
    Integration into RiZone
    Note: Technical deviations in terms of cooling output, dimensions or weight are possible for unit types with free cooling
    The performance data for the chosen option package varies and should be taken from the IT chiller configurator. We reserve the right to make technical modifications
    Pump and tank may be selected as options with IT chillers, the relevant technical specifications apply to these configuration variants
    Air throughput (unimpeded air flow): At 50 Hz: 10,880 m³/h
    Dimensions: Width: 810 mm
    Height: 1,542 mm
    Depth: 1,800 mm
    Operating temperature range of cooling medium: 5 °C...15 °C
    Operating temperature range: -20 °C...43 °C
    Permissible operating pressure (p. max.): 28 bar
    Power consumption Pel: At 50 Hz: 6.9 kW
    Packs of: 1 pc(s).
    Weight/pack: 400 kg
    Customs tariff number: 84186900
    EAN: 4028177682214
    ETIM 7.0: EC002516
    ECLASS 8.0: 27180713
    Product description: SK Chillers for IT cooling, 15 kW, 400 V, 3~, 50 Hz, WHD: 810x1542x1800 mm

    + Approvals

    Declerations:
    Declaration of conformity: 
    DE, EN

    + Downloads / CAD

    Data Sheets:
    Technical system catalogue: 
    DE EN

    + Tender texts

    Cold water generation
    Chiller in compact design
    for recooling of circulation water, factory assembled,
    internally wired, provided with oil and refrigerant,
    pressure-tested.
    Highly robust design thanks to redundant components.
    Cooling unit especially designed for requirements in
    the IT field in conjunction with Rittal Liquid Cooling
    Package (LCP)
    Consisting of:
    Solid enclosure made of section plates with louvre
    plates on both sides as air inlet and transportation
    holes in the base/plinth.
    Two compressors with suction cooled gas, fully
    hermetically sealed compressors mounted on vibration
    dampers with crank case heaters as "tandem (50 %
    - 50 %).
    Evaporator as plate heat exchanger with stainless
    steel plates, copper soldered, diffusion tight
    insulation with electrical heating element.
    High-performance condensor, air-cooled (copper pipe
    with aluminium fins), with two speed-controlled axial
    fans, air inlet from both sides, blowing out towards
    the top.
    One refrigerant circuit of soft copper pipe, silver
    soldered, equipped with refrigerant collector, dryer,
    inspection glass, security valve, liquid magnetic valve
    and thermostatic expansion valve with MOP, service
    valves and blocking valves on the suction and pressure
    side of the compressors. High-pressure pressostats,
    Low-pressure pressostats in TÜV tested design.
    Control integrated in a compact enclosure made of
    spray-finished sheet steel IP54 in RAL 7035 (Rittal or
    comparable design).
    Enclosure and control unit accessible from the front
    and wired to VDE/IEC standard.
    Micro-processor controller Carel PC05 electronic
    board with digital display and SNMP interface
    card for monitoring and controlling the complete unit.
    5 floating contacts for collective fault signal,
    pumps, cooling circuit, excess temperature and filling
    pressure fallen below,
    24 V AC control voltage,
    red lamp "collective fault signal",
    remote control on/off,
    cable marking with marking systems,
    cable entry in the front panel,
    all motors with motor circuit breaker,
    electromagnetic consumer with RC circuit,
    main switch, red/yellow,
    flow monitor for pump and evaporator protection,
    sensor in water inlet and water outlet,
    antifreeze probe to protect evaporator,
    redundant connection of several units (max. 8) via
    master/slave control possible.
    Interface to the building control system via Rittal
    CMC or SNMP interface possible.
    Water circuit as pressure-sealed system with steel
    tank.
    Two highly efficient inverter pumps with "Viton" seal
    in redundant design with switching to even
    utilisation,
    blocking valve in front of and behind the pumps,
    non-return valve at the pump outlet,
    automatic bypass valve,
    expansion tank, safety valve and exhaust fan,
    draining device and filling connection for water
    internal,
    water connections in the rear panel,
    water pressure manometer 0 - 10 bar,
    water pressure monitoring via pressure transmitter in
    the water entry, piping and components completely
    isolated.
    Fluid: Rittal Rifrost standard SK3301.960 for indoor
    use or outdoor SK3301.950 for outdoor use; as an
    alternative water according to the German standard in
    water quality with an additive of 20% to maximum 35% of
    Antifrogen N from Clariant. In general it is also
    possible to use other additives after prior arrangement
    with and approval of Rittal. An inappropriate fluid
    can lead to damages at the gaskets etc.
    Enclosure: Industrial enclosure painted in RAL7035
    with rubber anti-vibrating mounts, fixed below
    the unit.
    We recommend outdoor siting with an additional rain roof
    as weather protection, special fencing and anchoring
    to the ground (not in our delivery part).
    Transportation: to lift the chiller a forklift can be
    used or passing strong enough belts below the unit.
    Documentation:
    General description
    Data sheet
    Hydraulic scheme, Legend
    Wiring plan
    Controller description
    Parameter list
    Spare parts list
    German and English language
    CE Declaration of Conformity
    Test protocol
    Directive taken into account:
    Machinery Directive 2006/42/EC
    Low Voltage Directive 2006/95/EC
    EMC Directive 2014/30/EC
    Pressure Devices Directive 2014/68/EC
    Technical specifications: Cooling output at Tw=15°C,
    Tu=35°C 15 kW Cooling output at Tw=25°C, Tu=35°C
    16,5 kW Rated operating voltage +/-6% 400V / 50Hz / 3~
    Control voltage +/-10%, 24 V AC / 50 Hz Power
    consumption at Tw=15°C, Tu=35° 6.9 kW Rated current
    max. 23 A Start-up current 59 A Refrigerant R407C
    Number of compressors 2 Capacity steps % 0-50-100%
    Number of axial fans 2 Pump capacity, 60 l/min Pump
    pressure, external 2.5 bar Power consumption pump
    0,9 kW Tank capacity, 48 l Temperature range +5°C - +20
    Ambient temperatures - Operating conditions -20°C -
    +43°C Ambient temperatures - Transport, storage,
    -20°C - +60°C Dimensions with base/plinth (W x H x D),
    810 x 1542 x 1560 mm Base/plinth height, 100 mm
    Water connections (internal thread), 1 1/2" Weight 400 kg
    Air throughput of fans 10880 m³/h Sound pressure
    level in a 10 m distance 53 dB(A) Protection
    (Electric) IP 54 for all electrical components
    Material piping Copper, brass and piping
    Design: Rittal SK 3232.701 or comparable
    Options:
    Hydraulic system kit I: 1 inverter pump
    Hydraulic system kit II: 2 inverter pump
    Hydraulic system kit IV: 2 standard pumps
    High efficiency Free-Cooling kit: Free cooling external,
    change-over to free cooling at ambient temperature of 2K
    below the water inlet temperature;
    3-way-valve and controlling are integrated in the chiller,
    ambient sensor delivered loose (in the electrical
    cabinet) with 5 m cable.
    Technical alteration with external free cooling:
    Cooling output in compressor operation at Tw=15°C,
    Tu=35°C 15 kW, Cooling output free cooler at Tw=15°C,
    Tu=10°C 21,5 kW, max. power consumption in free cooling
    operation 2,28 kW, max. current in free cooling
    operation 4,1 A, air flow direction (to be indicated)
    vertical or horizontal
    Buffer store of steel, insulated, for separate siting;
    volume 500 l, Dimensions D x H = 850 x 1980 mm in
    accordance with data sheet;
    Supplied loose: Safety assembly and pressure
    compensating tank.
    Emergency cooling kit via mains water infeed: Plate
    heat exchanger with magnetic valve (24V AC) NC and
    pressure switch (on a floating contact) for
    integration into the return pipe (LCP). Installed in a
    separate housing
    Municipal water conditions:
    max. 8°C, min. 2.0 bar - max. 6 bar,
    Special voltage 460V / 60Hz
    UPS kit: power infeed divided into two parts - for
    compressor and fan, and for control and pump for UPS
    connection, switching over by software. (Attention
    Must only be used in conjunction with speed-controlled
    pumps!)
    RiZone efficiency monitoring kit: consisting of
    additional sensors to show the energy efficiency
    of the chiller, the datas are available by SNMP.

     Chillers for IT cooling