Micro Data Center Level E

Model No. 7999.009

  Product Lifecycle  
Customized
  • Micro Data Center Level E

    This product is used in industry/IT projects. Please contact your sales representative for further information.

    Close
    Product details

    The IT Safe MDC Level E is a small data centre, perfectly tailored to your requirements, with an optimised footprint that expands as your IT develops, and can also be relocated to a different site when necessary.

    + Product description

    Product description: The Micro Data Center Level E (MDC Level E) is a modular security safe with an operator door at the front and service door at the rear. The MDC Level E is supplied with one cable entry in each side element as standard and is available in a range of sizes.
    Benefits: Suitable for installation at poorly accessible sites
    Expandability for graduated investment in line with IT growth.
    Prepared for the installation of various IT climate control solutions
    Systems may be dismantled and reassembled, for maximum investment security
    Applications: A high level of protection against potential physical threats for IT
    Targeted configuration components transform the safe into a complete, compact data centre.
    Material: Sheet steel, coated
    Colour: Enclosure: RAL 7035
    Service door: RAL 7035
    Operator door: RAL 7035
    Supply includes: Security safe with operator door and servicing door
    Cable entry in both side elements
    Both doors with key lock
    Options: Different lock variants
    Different cable entry systems
    Cable entry in the top and base unit
    Twin-walled doors
    Choice of door hinges
    Supporting structure
    Supporting structure with fire protection
    Note: The tests were performed as system tests and confirmed with test reports.
    Project planning on request
    Protection standards: The safe was tested as a system.
    The single safe was tested as a system with one single-leaf door and one bifold door and mechanical lock
    Fire resistance class F 90 to DIN 4102 Part 2, compliance with limits ΔT < 50 K, rel. humidity < 85% over 30 minutes
    Smoke protection based on DIN 18095-2: 1991-03
    Burglar resistance RC 2, tool attack analogous to DIN EN 1630:2011-09
    Burglar resistance RC 3 tool attack analogous to DIN EN 1630: 2011-09 (restricted configuration options)
    Clearances: Installation height for components: 47 U
    Standard protection from: Fire
    Extinguishing water
    Corrosive gases
    Vandalism
    Unauthorised access
    Dust
    Theft/burglary
    IP protection category to IEC 60 529: IP 56
    Packs of: 1 pc(s).
    EAN: 4028177717084
    ETIM 7.0: EC002499
    ECLASS 8.0: 27180207
    Product description: Micro Data Center Level E. The Micro Data Center Level E (MDC Level E) is a modular security safe with an operator door at the front and service door at the rear. The MDC Level E comes with one cable entry in each side element as standard.

    + Downloads / CAD

    Data Sheets:
    Documentation:
    Instructions: 
    DE EN

    + Add accessories

    + Tender texts

    Micro Data Center Level E
    Item number: 7999.009
    IT - SECURITY SAFE
    Supply of a modular IT security safe.
    Fire protection F 90 tested according to DIN 4102 (ISO time-temperature
    curve) but 30 minutes within the limits of 50 K temperature increase and
    85% relative humidity. Furthermore, proof of tested burglary protection
    RC 2, based on EN 1630, must be provided.
    According to EN 60529, the protection class of the housing (at least IP
    56) must be fulfilled.
    All tests must be carried out as system tests.
    The values achieved must be verified with test certificates.
    The IT security safe must be of modular, "steel in cassette" design for
    free-standing installation.
    A demountable, as well as expandable construction must be proven.
    Installation around existing, commissioned IT components is required.
    Decommissioning of the IT components during installation is not
    possible!

    The IT security safe must have two security doors, one at the front and
    one at the back. These security doors must be equipped with an
    appropriate access control system.

    The connections of the elements of the IT security safe are to be
    designed using form-fit connection techniques that can be released at
    any time.

    The ingress of extinguishing water and moisture, as well as corrosive
    fumes into the modular IT safety safe, must be prevented by design
    measures.

    Technical features
    The following features must be provided:

    Housing dimensions outside:
    Height: 2210 mm / 2410 mm
    Width: 1100 mm (single safe, without attachments)
    Width: 2200 mm (linkage of 2 safes, without attachments)
    Width: 3300 mm (linkage of 3 safes, without attachments)
    Width: 4400 mm (linkage of 4 safes, without attachments)
    Depth: 1204 mm / 1404 mm (without attachments)

    Housing dimensions inside:
    Height: 2030 mm / 2230 mm (42 U / 47 U)
    Width: 920 mm (single safe)
    Width:1840 mm (linkage of 2 safes)
    Width: 2760 mm (linkage of 3 safes)
    Width: 3680 mm (linkage of 4 safes)
    Depth: 1000 mm / 1200 mm

    The IT security safe must have the possibility of stringing together
    several safes. The modules arranged in relation to each other must have
    large inspection openings for the cabling of the network racks located
    in the interior. Test certificates must be provided for the baying of
    the safety safes.

    The IT security safe must be designed in such a way that it is also
    possible to add further modules at a later date.

    It must be ensured that the existing network or server rack does not
    have to be relocated as part of the expansion, unless the conditions on
    site require this.

    The expandability of the existing system must be guaranteed for at least
    5 years.

    The IT security safe must have a cable entry system at several positions
    of the safe. The cable duct systems must be designed in an "open
    construction", suitable for installation with already installed IT
    components. The cable duct systems have to be fireproof, waterproof and
    gas-resistant for the introduction of data, control and supply cables
    into the modular IT security safe.

    A duct material that allows later retrofitting to data and supply lines
    is to be used as sealing material.

    Cable entry
    Standard (this version is already included)
    Cable entry arranged in the rear area of the side elements designed as
    soft duct
    Variant 1
    Cable entry arranged in the rear area of the side elements designed as
    hard duct
    Variant 2a
    Cable entry arranged in the head element designed as a hard duct (in
    addition to the standard)
    Variant 2b
    Cable entry arranged in the bottom element designed as a hard duct (in
    addition to the standard)
    Variant 3
    Cable entry arranged in the rear area of the side elements designed as a
    cable box

    To provide an adapted process climate on the inside of the IT security
    safe, a cooling unit in split design must be provided.
    The inner and outer circuits are hermetically separated. The evaporator
    part must be located on the inside of the IT - safety safe, while the
    condenser is placed outside the safe or the building.
    Alternatively, a solution with cold water cooling must be provided.

    Closure version

    Standard (This version is already included)
    The locking mechanism is designed as a safety lock with 2 keys each. The
    locks of the operator and service door are not keyed alike.

    Variant 1
    The locking mechanism (operator and/or service door) is designed as an
    electronic key combination lock with mechanical revision opening by
    means of an emergency key.

    Variant 2
    The locking mechanism (operator and/or service door) is designed as an
    electronic lock which must be controlled by means of an access control
    system provided by the customer.

    Operator and service door version

    Standard (This design is already included in item 1.1)
    Door in single-leaf design.

    Variant 1
    Door in double-leaf design

    Burglary protection
    Modular security safe with tested burglary protection in accordance with
    EN 1627. A system test must be verified.

    Standard (This version is already included)
    Burglary protection RC 2 in accordance with EN 1630

    optional
    Burglary protection RC 3 following EN 1630 (reduced configuration)

    Errors and technical modifications excepted.

     Micro Data Center Level E

    Model No.

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree

    Close