Fire alarm and extinguisher system DET-AC III master

Model No. 7338.121

  Product Lifecycle  
Active
  • Fire alarm and extinguisher system DET-AC III master
  • Fire alarm and extinguisher system DET-AC III master
    Product details

    Compact fire alarm and active extinguisher system with smoke extraction system, built into one height unit for use in security safes and closed server racks.

    + Also required

    + Product description

    Product description: The active extinguisher system includes the smoke extraction system and the extinguisher unit. The smoke extraction system is identical to the smoke extraction system in the EFD III. The extinguishing process begins automatically when a main alarm is activated. For the extinguishing process, the tank is pressurised via a propellant cartridge. The extinguisher gas Novec™ 1230 evaporates at the extinguisher nozzle and is distributed in the server enclosure.
    Benefits: Early fire detection
    Automatic extinguishing
    Innovative extinguisher Novec™ 1230: eco-friendly, non-critical for IT components, non-conductive
    482.6 mm (19") rack mount with just 1 U
    Tested by VdS Schadenverhütung GmbH
    CAN bus interface to the CMC III monitoring system
    Floating relay outputs (pre-alarm/main alarm/collective fault)
    Technical specifications: Extinguisher is emitted via a propellant cartridge, with integral electrical activation unit
    Integral extinguisher monitoring (indication of >15% loss)
    Material: Sheet steel
    Colour: Enclosure: RAL 7035
    Front: RAL 9005
    Extinguisher gas: Type: Novec™ 1230
    Fill volume: 1.8 l
    Tank: Material: Aluminium
    Volume: 2 l
    Interfaces: 4 x/3 x relay outputs for alarms and faults (terminals/RJ12 jacks)
    1 x/1 x input for door contact switch (terminal/RJ12 jack)
    2 x CAN connections for master-slave networking
    2 x connection (external alarm/manual triggering device)
    1 x voltage output for DET-AC slave III (24 V DC max. 500 mA)
    1 x USB
    2 x CAN bus interfaces to CMC III (max. 16 on PU/4 on PU Compact)
    Uninterruptible mains electricity operation: approx. 4 h
    Note: This system is designed solely for use in closed, non-accessible enclosure systems with a maximum volume of 2.8 m³.
    Display: Plain-language display with 6 LEDs
    Sensors: Optical smoke detector (sensitivity: approx. 3.5%/m light obscuration)
    Optical smoke detector HS (sensitivity: approx. 0.25%/m light obscuration)
    Dimensions: Width: 482.6 mm
    Height: 44 mm
    Depth: 660 mm
    Operating temperature range: 10 °C...40 °C
    Storage temperature range: -20 °C...65 °C
    Storage temperature range of batteries: -15 °C...40 °C
    Relative humidity (non-condensing): 96 %
    Rated operating voltage: 100 V - 240 V, 1~, 50 Hz/60 Hz
    Air flow monitoring: approx. ±10% of total airflow
    Packs of: 1 pc(s).
    Weight/pack: 21.5 kg
    Customs tariff number: 84248970
    EAN: 4028177699311
    ETIM 7.0: EC002685
    ECLASS 8.0: 40040104
    Product description: DET-AC III Master, fire alarm and extinguisher system, active smoke extraction system, early fire detection, automatic extinguishing.

    + Approvals

    Certificates:
    VDS: 
    DE, EN
    Declerations:
    Declaration of conformity: 
    DE, EN

    + Downloads / CAD

    Data Sheets:
    Safety data sheet: 
    DE EN FR
    Technical details: 
    CS DA DE EN ES FI FR HU IT NL NO PL RU SV TR ZH
    Visio Shapes: 
    DE, EN
    Documentation:
    Instructions: 
    DE EN ES FR IT

    + Tender texts

    DET-AC III Master fire alarm and extinguisher system

    The fire alarm and extinguisher system is able to detect and extinguish
    fires at an early stage. The compact system occupies 1 U of rack space
    and is designed for installation in the 19" level of closed server
    enclosure systems.
    An integrated fan continuously draws in air from the protected space via
    a pipe system. This air passes two smoke detectors. If smoke aerosols
    are detected, the high-sensitivity smoke detector triggers a pre-alarm
    state. The second smoke detector triggers the main alarm and activates
    the extinguishing process. The proper functioning of the smoke detectors
    is monitored continuously by the evaluation and control electronics on
    the control board.
    The extinguishing agent used is NOVEC 1230, which is held in liquid form
    in the tank. When extinguishing is activated, the tank is pressurised.
    The extinguishing agent vaporises at the nozzle and spreads through the
    protected space.
    The extinguishing nozzle is located in the front panel of the unit. The
    frame for installation of the active extinguishing system is designed as
    a 19" rack module. The depth of the system is such that it can be
    installed in 19" server enclosures with an internal depth > 800 mm.
    The pre-assembled system can be inserted or removed without interrupting
    operation of the equipment to be protected.
    A CAN bus interface enables direct connection to the Rittal CMC III
    system.
    The fire alarm and extinguisher system has been tested by VdS
    Schadensverhütung GmbH. All tests were completed with a positive result.
    A USB port offers a possibility to retrieve information on operating
    states and events, as well as to perform various settings. To this end,
    a special maintenance program is made available for use by appropriately
    trained personnel.
    The commissioning must be carried out by Rittal.
    Technical data:
    Width: 482.6 mm (19")
    Height: 44 mm (1 U)
    Depth: 660 mm
    Housing material: Sheet steel
    Weight: approx. 15.5 kg
    Rated voltage: 100 - 240 V AC, 50/60 Hz
    Emergency power supply: approx. 4 h
    Max. permissible active current: 1.0 A at 24 V (the sum of all connected
    devices must not exceed the permissible active current of 1.0 A)
    Max. permissible charging current: 350 mA at 24 V
    Ambient temperature:
    +10 °C to +40 °C (operation)
    -20 °C to +65 °C (storage without batteries)
    -15 °C to +40 °C (battery storage)
    Humidity: up to 96% (relative), non-condensing
    Protection category: IP 30
    Connections:
    Terminal for relay output "Pre-alarm", "Fire alarm", "Extinguishing"
    Terminal for relay output "Collective fault"
    Terminal for door contact switch
    Socket (RJ 12) for connection of door contact switch
    3x sockets (RJ 12) for signal outputs "Fault", "Pre-alarm", "Main alarm"
    2x CAN connection for system networking
    Connection for external alarm device
    Connector for manual alarm
    Voltage supply (UB), max. 500 mA
    USB port
    CAN bus interface to CMC III
    Displays:
    1 plain-language display for status messages
    1 LED green, "Operation"
    1 LED yellow, "Shutdown"
    1 LED red, "Extinguishing system primed"
    1 LED red, "Extinguishing system activated"
    1 LED yellow, "Blocked"
    1 LED yellow, "Fault"
    Sensors (2 different scattered-light sensors for 2 alarm thresholds):
    Optical smoke detector
    (sensitivity: approx. 3.5%/m obscuration)
    Optical smoke detector HS
    (sensitivity: approx. 0.25%/m obscuration)
    Air flow monitoring: approx. +/-10% of overall air flow
    Protected space volume: max. 2.8 m3 (protected space must not display
    any recognisable
    openings)
    External devices:
    Connection for manual alarm
    Connection for door contact
    Connection for external alarm device
    CAN bus interface to Rittal CMC III
    Tank material: Aluminium
    Empty volume: approx. 2.0 litres
    Content: approx. 1.8 litres Novec 1230
    Extinguishing agent discharged via pressure from propellant cartridge
    Integrated electrical activation unit
    Integrated extinguishing agent leakage/filling level monitoring
    (display from >15% loss)
    Model No.: 7338.121
    Manufacturer: Rittal GmbH & Co. KG

     Fire alarm and extinguisher system DET-AC III master

    Model No.

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree