Fan module for LCP Rack/Inline CW

Model No. 3312.016

  Product Lifecycle  
Passive
  • Fan module for LCP Rack/Inline CW

    Discontinued article.

    Information on the discontinued articles
    Product expires on 31.01.2023

     

    Close
    Product details

    Increased cooling output. Additionally redundancy can be achieved or the electric power consumption can be reduced.

    + Product description

    Product description: To increase the cooling output, individual fan modules may be retro-fitted into the LCPs. Additional integration can also achieve redundancy or reduce the electric power consumption of the LCPs.
    Benefits: May be connected with the system operational
    Tool-free replacement of the fan modules
    Function principle: Installing fan modules in an LCP increases the air throughput and hence the cooling output of the chosen variant. With an adequate cooling output, fan modules may be added to create redundancy. Retro-fitting additional fans over and above the required volumetric air flow allows you to reduce the electrical energy consumption, since the fans then operate at a lower speed. At the same time, the noise level of the unit will be significantly reduced.
    Colour: RAL 9005
    Supply includes: 1 fan unit
    EC fan
    Fully wired ready for connection
    Assembly parts
    Packs of: 1 pc(s).
    Weight/pack: 7,9 kg
    Customs tariff number: 84145915
    EAN: 4028177811515
    ETIM 7.0: EC000320
    ECLASS 8.0: 27180716
    Product description: SK Fan module, UL, for LCP R15, RAL 9005

    + Downloads / CAD

    + Tender texts

    LCP fan module, 3312.016
    for LCP Rack / Inline CW 3312.130/230/250/260/530/540/550/560

    LCP Fan module 3312.016:
    The fan module is suitable for the LCP Rack / Inline CW.
    The additional installation of fan modules into an LCP increases the air
    throughput and thus the cooling output of the respective variant.
    If there is already sufficient cooling capacity, the addition of fan
    modules can help to form redundancies.
    Furthermore, by retrofitting fans beyond the required volumetric air
    flow, the electrical energy consumption can be reduced as the fans then
    work at a lower speed.
    Similarly, the noise level of the device is clearly reduced.
    The cooling module is quickly and easily installed without tools, so
    minimising maintenance time.

    LCP module, packaging unit consisting of:
    An EC technology fan module with the necessary mounting material
    Colour: RAL 9005

     Fan module for LCP Rack/Inline CW

    Model No.

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree

    Close