CMC III sensors

Model No. 7030.110

  Product Lifecycle  
Active

+ Also required

+ Product description

Design: Temperature sensor
Benefits: Fast connection and automatic detection via plug & play
Power is supplied via the CAN-BUS interface.
Applications: Enclosure monitoring in IT, industry and facility management
Monitoring of enclosures, rooms and containers in the IT environment
Function principle: Settings can be made via the CMC III processing unit or IoT interface
The CMC III temperature sensor monitors the ambient temperature in the enclosure.
With a passive airflow the integrated sensor in the enclosure can be used. For applications without an active airflow, the external NTC sensor provided must be connected.
Measurement range for external sensors: -40 °C...+80 °C
Material: Plastic
Front: Smooth
Enclosure: Textured
Colour: Front: RAL 9005
Enclosure: RAL 7035
Supply includes: Sensor
Mounting plate
Assembly parts
External temperature sensor with connection cable and connector
NTC sensor, length 1.80 m
max. cable length 2 m
Connection to the CAN bus: Direct
Interfaces: 2 x RJ45 CAN bus
Jack
No. of participants per IoT interface (max.): 32
No. of participating PU compact (max.): 4
No. of participating PU (max.): 32
No. of PDU devices (max.): 16
Measuring technique: internal NTC resistor
external NTC resistor
Dimensions: Width: 80 mm
Height: 30 mm
Depth: 40 mm
Operating temperature range: 0 °C...55 °C
Ambient humidity (non-condensing): 5...95 %
Packs of: 1 pc(s).
Weight/pack: 0.201 kg
Customs tariff number: 90269000
EAN: 4028177659483
ETIM 7.0: EC002627
ECLASS 8.0: 27189253
Product description: DK CMC III Temperature sensor, WHD: 80x28x40 mm

+ Approvals

Approvals:
UL + C-UL (listed): 
EN
Declerations:
Declaration of conformity: 
DE, EN EN
Manufacturer's declaration: 
EN

+ Downloads / CAD

Data Sheets:
Graphics: 
DE
Documentation:
Instructions: 
DE EN RU
Quick guide: 
DE, EN, FR RU

+ Tender texts

7030.110
CMC III temperature sensor with CAN bus
Packs of 1
Compact plastic housing with ventilated front in RAL 9005.
Housing in RAL 7035,
The sensor has two RJ45 connections with an integrated CAN bus. The
sensor is automatically detected by the
CMC III system, the Processing Unit, and is provided with a sequential
number in the bus sequence. Integrated multi-colour LED as status
display.
An NTC temperature sensor is integrated into the sensor housing to
measure the airflow temperature.
An external NTC temperature sensor with connection cable is also
enclosed. When this external sensor is plugged in, the internal
temperature sensor is switched off.
The power supply is ensured by connection to the CAN bus for the
Processing Unit.
The warning and alarm limit values can be set via the software for the
CMC III Processing Unit, however they are saved in the sensor itself.
Technical specifications:
NTC resistor: 10 k Ohm at 25 °C
Temperature measurement range (internal sensor): 0 °C to 55 °C
Temperature measurement range (external sensor): -40 °C to 80 °C
Measurement precision: +/- 2 °K between 10 °C and 40 °C for external
sensor
Resolution: 0.1 °K
Jack for external sensor: 1
CAN bus jacks RJ45: 2
Protection category: IP 30 to IEC 60 529
Temperature application range:
0 °C to 55 °C
Humidity range:
5% to 95% relative humidity, non-condensing
WxHxD: 80 x 28 x 40 mm
Included in the pack: Sensor, temperature sensor with 2 m connection
cable and plug, quick reference guide and universal mounting set

 CMC III sensors

Model No.

Close
+
[X] Close

Required 

$nbsp;

Product data (ZIP)

Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

 I agree

Close