More on the product
Create PDF of this page+ Product description
Material: |
Polyamide Fire protection corresponding to UL 94-V0 |
---|---|
Colour: | RAL 7035 |
Type of electrical connection: | Box terminal |
Rated current max.: | 100 A |
Rated operating voltage: | 690 V, 3~ |
Electrical ratings UL (SCCR): | 65 kA - 480 V, Manual Motor Controller max. 100 A, NLRV/7 |
Cable outlet: | Top |
For bar systems with centre-to-centre spacing: | 60 mm |
Note: |
Cable outlet: Switch outlet or as outgoing cable from the switchgear The technical data may vary for UL applications |
Number of poles: | 3-pole |
For universal switchgear application: | yes |
Dimensions: |
Width: 72 mm Height: 210 mm |
Connection for round conductor cross-sections: | 10 ‐ 35 mm² |
Clamping area for laminated copper bars (W x H): | 10 x 7.8 mm |
To fit busbars: | Height: 5, 10 mm |
To fit manufacturer (model): |
ABB (MS 495, MS 496, MS 497) Eaton (PKZ2) Schneider Electric (GV3ME80) Siemens (S3) |
Packs of: | 1 pc(s). |
Weight/pack: | 0,58 kg |
Copper weight (kg per piece): | 0.114 |
Customs tariff number: | 85369095 |
EAN: | 4028177503694 |
ETIM 7.0: | EC001531 |
ECLASS 8.0: | 27370304 |
Product description: | SV Circuit-breaker component adaptor, 100 A, 690 V, 3-pole, cable outlet top, round conductor connection 10-35 mm², clamping area WH: 10x7,8 mm |
+ Approvals
Approvals: | |
---|---|
Declerations: |
+ Add accessories
+ Tender texts
Circuit-breaker component adaptor up to 100 A
CB component adaptor up to 100 A, 3 pole,
cable outlet at the top
for busbar thickness 5/10 mm and PLS 800/1600
Type of connection
Connection clamp: Box terminal
Round conductor: 10 - 35 qmm
Clamping area for laminated copper bar:
10 x 7.8 mm
For UL applications: AWG 2-6
Technical specifications
Construction width: 72 mm
Length: 210 mm
Electrical parameters
For IEC applications:
Rated current: up to 100 A
Rated operating voltage Ue: AC 690 V
For UL applications:
Rated current: up to 100 A
Rated operating voltage Ue: AC 600 V
System:
Rittal RiLine60
CB component adaptor up to 100 A, 3 pole,
cable outlet at the top
for busbar thickness 5/10 mm and PLS 800/1600
Type of connection
Connection clamp: Box terminal
Round conductor: 10 - 35 qmm
Clamping area for laminated copper bar:
10 x 7.8 mm
For UL applications: AWG 2-6
Technical specifications
Construction width: 72 mm
Length: 210 mm
Electrical parameters
For IEC applications:
Rated current: up to 100 A
Rated operating voltage Ue: AC 690 V
For UL applications:
Rated current: up to 100 A
Rated operating voltage Ue: AC 600 V
System:
Rittal RiLine60