RiMatrix S Standard security room

Model No. 7998.306

  Product Lifecycle  
Expired
  • RiMatrix S Standard security room
    Product details

    The standardised data centre at your premises is equipped with an additional security room (room-within-a-room) to provide additional protection from fire, water and smoke.

    + Product description

    Product description: The standardised data centre at your premises is equipped with an additional security room (room-within-a-room) to provide additional protection from fire, water and smoke.
    Material: Element core made of thermally effective insulation substance
    Robust, encapsulated sheet steel cassette panels
    Innovative connection technology using patented profile technology
    Use of temperature- and humidity-resistant seals
    Use of fire protection valves
    Dismantling and reassembly is possible at any time
    Supply includes: Advice and ROI calculation
    Delivery and integration into the customer infrastructure
    Commissioning and handover
    Documentation, training and instruction
    Hotline and service/service agreements
    Clearance depth: 7.220 mm
    Clearance height: 2.700 mm
    Clearance width: 2.750 mm
    Climate control (ZUCS): 60 kW + 10 kW
    n+1 redundant
    Number of low-voltage main distributors: 1
    No. of PDU Basic: 14
    Serverracks (600x2000x1200mm): 6
    Combined network/server rack (800 x 2000 x 1200 mm): 1
    Protection standards: Fire resistance EI 90 to EN 1363/F 90 to DIN 4102
    Dust- and watertight IP 56 to IEC 60 529
    Protection from unauthorised access – Resistance class II
    EMC basic protection
    Acrid gas-tightness, based on EN 1634-3 (DIN 18095)
    Shock test with 3000 Nm energy after 30 minutes flame impingement over standard temperature curve
    Burglar resistance: RC 2
    Design burglar protection: yes
    Design fire protection: EI 90 to EN 1363 / F 90 to DIN 4102
    Humidification and dehumidification system: optional
    Room extinguisher system: optional
    Design UPS: 60 kW + 20 kW
    n+1 redundant
    Version: Single 6
    Dimensions: Width: 2,950 mm
    Height: 2,800 mm
    Depth: 7,420 mm
    Packs of: 1 pc(s).
    Customs tariff number: 85480090
    EAN: 4028177702493
    ETIM 7.0: EC002499
    ECLASS 8.0: 27180207
    Product description: DK RiMatrix S Standard security room, Single 6

    + Downloads / CAD

    + Tender texts

    Standard data centre 60 kW, 6+1 racks,
    including cooling and UPS, installed in a security
    room ,,
    ,,

    Fully functional data centre comprising an ITC
    climate zone for the server and network systems, and a
    separate technical climate zone for the UPS equipment
    and low-voltage switchgear.

    The ITC climate zone comprises a rack suite (depth
    1200 mm) with 6 server racks and a network rack, and
    is fully isolated from the climate zone for the
    electrical equipment by way of self-closing sliding
    doors in the cold and hot aisles.

    The standard data centre is enclosed in an accurately
    dimensioned, modular IT security room. All connecting
    elements of the room systems are designed to permit
    disassembly and re-use. The enclosure is a steel box
    construction. The IT security room is installed as a
    room-in-room system and serves to eliminate
    potential physical threats. A partition which passes
    over the rack systems achieves targeted separation of
    the climate zones.
    The following qualities are tested and certified in
    accordance with the specified requirements:
    Fire protection F90 to DIN 4102
    Burglar resistance WK2 to ENV 1630
    Dust ingress IP5X to EN 60529
    Water ingress IPX4 to EN 60529
    Acrid gas-tightness in line with DIN 18095
    Electromagnetic compatibility (EMC) as per test
    certificate in respect of high-frequency interference
    and susceptibility

    All proof of compliance is to be presented in the form
    of system certification.
    This serves to confirm the test and certification
    conformity of the IT security room, including all
    installed modules (door, cable and piping bulkhead,
    climate control, overpressure relief). Cable and
    piping entry is realised in accordance with the
    required properties of the room system. Access doors
    are designed as fire protection doors, with hinges on
    the left-hand side (DIN definition) and without stay,
    in accordance with the aforementioned test criteria.
    The door is opened by way of a semi-cylinder lock, or
    alternatively with electric control supplied by the
    customer. The climate control systems and overpressure
    relief for the case of extinguisher activation comply
    with the aforementioned test criteria. The relief
    device is closed without dependency on an external
    energy supply.

    The 600 mm wide hot aisle and the 950 mm wide cold
    aisle are partitioned within the security room
    and are to this end provided with a partitioning panel
    which passes over the server/network racks.

    The standard data centre incorporates a fully
    functional raised-floor construction, with air intake
    and outlet grilles in the form of dip-galvanised
    gratings.

    Air-circulating cooling units (CRAC systems) are
    installed in the cavity space of the raised floor. The
    CRAC systems do not occupy space within the rack (Zero
    U-Space Cooling Systems).

    A CRAC system is installed under each server rack.
    Each CRAC system offers a nominal cooling output of 12
    kW; the average heat load capacity per rack is thus 10
    kW, taking into account n+1 redundancy over the total
    number of CRAC systems.

    The intake temperature for cooling is 20°C, observing
    temperature limit values according to ASHRAE 2008
    (max. 27°C) within the cold aisle.

    The UPS climate zone possesses a further CRAC system
    to dissipate the UPS heat loss. Through direct
    injection of the UPS cooling air, a temperature level
    of max. 22°C is maintained within the climate zone, in
    accordance with the Eurobat guidelines on the
    environment for 10-year batteries.

    The cooled intake air is blown into the cold aisle by
    EC fans under the floor gratings. Flat filter fleeces
    are fitted between the fan grilles and the floor
    gratings to filter the circulating air.

    The intake temperature and speed of the EC fans are
    regulated by a controller in the standard data centre,
    which communicates with the controller of an optional
    chiller station via a system bus for purposes of
    energy efficiency optimisation. The controller is not
    accommodated in the IT racks and thus does not occupy
    rack installation space.

    The standard data centre is equipped ready for use
    with a cold piping system comprising polypropylene
    piping; the individual heat exchangers are connected
    by way of high-pressure hoses.

    Required chiller set provided by the customer:
    The standard data centre must be equipped with a
    straight ball valve to regulate the air intake
    temperature to the target value, a flowmeter and two
    temperature sensors to measure the coolant flow volume
    and the feed and return temperatures, as well as to
    calculate the heat output.

    Required chiller set must be supplied:
    The standard data centre must be supplied without ball
    valve and sensors for the coolant.
    The volume of the medium is regulated by the
    variable-speed pump of the chiller station of the
    standard data centre; the sensors are fitted in the
    chiller station.

    The standard data centre is equipped with a modular
    UPS system with 20 kW modules. The system provides for
    n+1 redundancy, and thus four UPS modules are supplied
    to cover the possible connected load of 60 kW for the
    ITC hardware.

    The UPS system possesses 10 battery strings with 28 Ah
    batteries, which are assigned jointly to all UPS
    modules and ensure autonomy for a period of 13
    minutes.

    The standard data centre incorporates switchgear with
    fused feeders for the installed rack suite. The
    switchgear spreads the feeders over two panels to
    establish an A/B power supply. The UPS system feeds
    supply path A. Supply path B must be connected to the
    mains supply via overvoltage protection.

    From the switchgear, the distribution busbars of the
    individual racks are wired ready for use and comprise
    Power Distribution Units with 24 C13 and 6 C19
    sockets. Each rack is provided with two PDUs to
    establish an A/B power supply.

    The power supply is routed above the racks. The data
    cables are routed to the IT racks separately from the
    power supply cables. The installation of the data
    cables is to be performed by the site
    operator/customer.

    Lighting and service socket are protected by way of an
    RCCB. Emergency lighting is installed.

    The standard data centre is equipped with an early
    fire detection system. To this end, air is drawn from
    the raised floor of the hot aisle via a perforated
    plastic pipe. The alarm is given by a monitoring
    system with Web access and SNMP interface.


    The standard data centre is assembled and installed
    directly on the customer's premises (without IT
    cabling; connection to the chiller and mains power
    supply are to be ordered separately).
    The room system is installed by certified personnel.
    Evidence of corresponding certification of the
    installation personnel is to be presented.

    Standard data centre version with 6+1 racks in a
    security room

    Outside dimensions Inside dimensions
    Length: 7420 mm Length: 7220 mm
    Width: 2950 mm Width: 2750 mm
    Height: 2800 mm Height: 2700 mm

    Walls without door require an assembly clearance of
    100 mm to the building walls. The roof of the
    enclosures requires an assembly clearance of 200 mm to
    the building ceiling.,,


     RiMatrix S Standard security room