TopTherm Blue e Roof-Mounted Cooling Unit Total cooling output 1706.07 - 13648.57 BTU/h

Model No. 3385.600

  Product Lifecycle  
Active
  • TopTherm Blue e Roof-Mounted Cooling Unit Total cooling output 1706.07 - 13648.57 BTU/h
    Product details

    Energy-efficient Blue e roof-mounted cooling units in output categories 500 W to 4,000 W with e-Comfort controller integrated as standard and electrical condensate evaporation.

    The product was added to your wishlist

    Model No.:

     
     
     
     
     

    No. of packs*

    Add to wishlist

    * Pack of sale = 1 pc(s).

    + Product description

    Product description: Energy-efficient Blue e roof-mounted cooling units with integral e-Comfort controller and electric condensate evaporation as standard.
    Benefits: May be linked to the IoT interface via the Blue e IoT adapter for cooling units with an output of 500 W or higher and e-comfort controllers
    Material: Stainless steel 1.4301 (AISI 304)
    Color: RAL 9007
    Supply includes: Condenser with hydrophobic RiNano coating
    Integral electric condensate evaporation
    Wired ready for connection (plug-in terminal strip)
    Drilling template
    Fasteners
    Total cooling output to DIN EN 14511: Cooling output L35 L35/50 Hz: 2 kW
    Cooling output L35 L35/60 Hz: 2.14 kW
    Cooling output L35 L50/50 Hz: 1.41 kW
    Cooling output L35 L50/60 Hz: 1.51 kW
    Rated operating voltage: 230 V, 1~, 50 Hz/60 Hz
    Note: Due to its low noise level, the roof-mounted cooling unit 3273.500 is also suitable for use in office applications.
    Rated current max.: At 50 Hz: 5.9 A
    At 60 Hz: 6.3 A
    Start-up current (max.): At 50 Hz: 19.7 A
    At 60 Hz: 17.9 A
    Air throughput (unimpeded air flow): External circuit: 1,760 m³/h
    Internal circuit: 470 m³/h
    Energy efficiency ratio (EER) 50/60 Hz L35 L35: Refrigeration factor L35 L35 (EER) 50 Hz: 2.09
    Refrigeration factor L35 L35 (EER) 60 Hz: 1.88
    Version: roof-mounted
    Dimensions: Width: 597 mm
    Height: 417 mm
    Depth: 475 mm
    Protection category IP to EN 60 529: External circuit, IP 34
    Internal circuit, IP 54
    Refrigerant/cooling medium: Refrigerant: R134a
    Quantity: 0.9 kg
    Global Warming Potential (GWP): 1,430
    CO₂ equivalent (CO₂e): 1.29 t
    Type of connection (electrical): Plug-in terminal strip
    Duty cycle: 100 %
    Temperature control: e-Comfort Controller (factory setting +35 °C)
    Operating temperature range: 10 °C...55 °C
    Storage temperature range: -40 °C...70 °C
    Setting range: 20 °C...55 °C
    Rated power Pel: Rated power L35 L35/50 Hz: 0.95 kW
    Rated power L35 L35/60 Hz: 1.14 kW
    Rated power L35 L50/50 Hz: 1.07 kW
    Rated power L35 L50/60 Hz: 1.23 kW
    Permissible operating pressure (p. max.): 28 bar
    Pre-fuse: Miniature circuit-breaker/fuse: 10 A
    Note on Model No.:: Delivery times on request.
    Packaging unit: 1 pc(s).
    Weight/packaging unit: 42 kg (92.6lb.)
    Customs tariff number: 84158200
    ETIM 7.0: EC000855
    ECLASS 8.0: 27180704
    Product description: SK cooling unit Blue e, roof-mounted, 6824 BTU/h, 230 V, 1~, 50/60 Hz, Stainless steel, WHD: 597 x 417 x 475 mm

    + Approvals

    Approvals:
    CSA: 
    EN
    UL + C-UL - FTTA: 
    EN
    UR + C-UR (recognized): 
    EN
    Certificates:
    EAC: 
    RU
    Declerations:
    Declaration of conformity: 
    DE, EN
    Declaration of conformity - F-gas regulation: 
    DE, EN
    Declaration of conformity UK: 
    EN

    + Downloads / CAD

    Data Sheets:
    Safety data sheet refrigerant: 
    CS DE EN ES IT JA PL SK
    Technical System Catalogue: 
    DE EN JA
    Technical details: 
    DE EN
    Documentation:
    Instructions: 
    CS DE EN ES FR IT JA NL PL PT SV TR
    Safety instructions: 
    Global
    White Paper: 
    DE EN

    + Add accessories

     TopTherm Blue e Roof-Mounted Cooling Unit Total cooling output 1706.07 - 13648.57 BTU/h

    Model No.

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree

    Close