Liquid Cooling Package LCP Inline CW

Model No. SK 3311.148

  Product Lifecycle  
Active
  • Liquid Cooling Package LCP Inline CW
  • Liquid Cooling Package LCP Inline CW
    Product details

    These highly efficient Inline units can create a cold curtain down a row rather than simply moving air into an aisle.Available in two versions: Flush, a configuration where the unit’s face matches that of the adjacent enclosures and air flows into the racks; and Protruding where the unit is bumped out 8 inches into the aisle and cool air flows from both sides across the face of nearby enclosures.The unit’s high-efficiency fans have been moved to the front of the LCP – on the cool side away from maximum heat – which will extend the life of the fans. Water connections are available at either the top or bottom of the unit.

    + Product description

    Benefits: Maximum energy efficiency due to EC fan technology and IT-based control
    Minimal area load due to low weight
    The separation of cooling and enclosure prevents water from entering the server enclosure
    Redundant temperature sensor integrated at the air end
    Fan modules configurable as n+1 redundancy.
    Targeted cooling output thanks to modular box-type plug-in fan units
    By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs
    Optimum adaptability due to dynamic, continuous control of the cold water volume flow
    Minimal pressure loss at the air end, which in turn minimizes the power consumption of the fans
    Up to 30 kW cooling output on a small footprint
    Top or bottom feed water connection
    Function principle: The hot air is drawn in from the room or hot aisle at the rear of the device and expelled at the front into the cold aisle after cooling. With this product, a raised floor is not necessary
    IT Monitoring: Monitoring of all system-relevant parameters such as server air intake temperature, server waste air temperature, water inlet/return temperature, water flow, cooling output, fan speed, leakage.
    Direct connection of the unit via SNMP over Ethernet
    Integration into RiZone
    Color: Exterior: RAL 9005
    Enclosure frame and interior: RAL 7035
    Protection category IP to IEC 60 529: IP 20
    Supply includes: Incl. 2 fan modules.
    Options: Various sensors
    Racks
    Variant: Row Cooling
    Total cooling output to DIN EN 14511: 18 kW (61418 BTU)
    27 kW (92127 BTU)
    30 kW (102364 BTU)
    L 30 L 22: 30 kW
    L 22 L 45: 30 kW (102364 BTU)
    Total cooling output/number of fan modules: 18 kW / 2 
    27 kW / 3 
    30 kW / 4 
    Total cooling output: 30 kW
    Air throughput: 2825 cfm (4 fans)
    Rated operating voltage: 208 V, 2~, 60 Hz
    230 V, 1~, 50 Hz/60 Hz
    Dimensions: Height: 2000 mm (79 ")
    Width: 300 mm (12 ")
    Depth: 1050 mm (41 ")
    Temperature control: Infinitely variable fan control
    2-way control ball valve
    Installation in bayed enclosure suite: Flush
    Temperature range: Water inlet: +15 °C
    Refrigerant/cooling medium: Cooling medium: Water
    Note: 18/27/30 kW
    Type of connection (electrical): Connector
    EC fan: yes
    Fans may be exchanged with the system operational: yes
    Water connections: DN 40 (G 1½" external thread)
    Number of fans: 2
    3
    4
    Packaging unit: 1 pc(s).
    Weight/packaging unit: 200 kg (440.9 lb.)

    + Approvals

    Approvals:
    UL: 
    (EN, US)

    + Downloads

    Data sheets:
    Product data sheet: 
    (EN, US)
    Documentation:
    Instructions: 
    (EN, US)
    Specialist literature:
    The Rittal technology library: 
    (US)

    + Add accessories


     
     
     
     
     
     
     

     Liquid Cooling Package LCP Inline CW

    Model No. SK 3311.148

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree

    Close