RiLineX connection adaptor

Št. artikla: RX 9361315

RiLineX connection adaptor for 60 mm busbar systems. The connection adaptor is single-pole and fits a double connection (round/sector-shaped conductor). The phase spacing is freely selectable. The unit is suitable for use with L1/L2/L3/N. The adaptor boasts an impressive compact design. Dismantling requires the use of tools. Conductors may be connected either from above or below. The connection clamps support full through-wiring. Mounted by simply snapping onto the RiLineX board. The adaptor is readily installed on RiLine60. It offers high levels of short-circuit protection and easy-to-fit contact hazard protection.

Št. artikla:
RX 9361315
Benefits
Mounting on the busbar system and cable connection with just one screw
Material
Polyamide (PA 6)
Fire protection corresponding to UL 94
Colour
RAL 9005
Rated current (guideline value, IEC)
864 A
Max. rated current of round conductor (IEC)
1.060 A
Max. rated current of round conductors (UL)
980 A
Note
The specified rated current as a guideline value is based on the recommended maximum operating current for single-wire cables with an admissible conductor temperature of 70 °C to IEC 61439-1, Table H.1 when laid horizontally in free air, at an ambient temperature of 55 °C.
The specified max. rated current (IEC) describes the recommended max. operating current of the terminal connection with a temperature rise limit of 70K to IEC 61439-1 (Table 6) for conductors laid in free air with clearance. Please note the maximum admissible insulation temperature.
Electrical ratings UL (SCCR)
27,5 kA - 600 V, RMS, unprotected
100 kA - 600 V, circuit breaker max. 600 A, DIVQ/7
100 kA - 600 V, Fuse Class L max. 2000 A, JDDZ/7
Cable outlet
Top/bottom
For bar systems with centre-to-centre spacing
60 mm
Number of poles
Single-pole
To fit busbar system
RiLineX
RiLine60
Dimensions
Width: 54.1 mm
Height: 119.4 mm
Depth: 163.4 mm
Connection of round conductors
95 ‐ 300 mm²
To fit busbars
15 x 10 mm
20 x 10 mm
30 x 10 mm
Rated voltage
1.000 V AC
1.500 V DC
600 V AC (UL)
600 V DC (UL)
Contamination level
3
Standards
IEC/EN 61439-1
UL 508
Rated impulse withstand voltage Uimp
12 kV
Rated insulation voltage Ui
1.000 V
Heat loss max.
105 W
IP protection category to IEC 60 529
IP 2X
Maximum operating air humidity
90 %
Operating temperature range
-5 °C...55 °C
Storage temperature range
-25 °C...75 °C
Ambient humidity (non-condensing)
10...90 %
Number of connections
2
Fire load
5,947 MJ/m²
Packs of
1 pc(s).
Net weight
0,8 kg
Gross weight
0,892 kg
PCF per pack (cradle-to-gate)
4.47
Customs tariff number
85369010
ETIM 9
EC001531
Product description
RiLineX connection adaptor for 60 mm busbar systems. The connection adaptor is single-pole and fits a double connection (round/sector-shaped conductor). The phase spacing is freely selectable. The unit is suitable for use with L1/L2/L3/N. The adaptor boasts an impressive compact design. Dismantling requires the use of tools. Conductors may be connected either from above or below. The connection clamps support full through-wiring. Mounted by simply snapping onto the RiLineX board. The adaptor is readily installed on RiLine60. It offers high levels of short-circuit protection and easy-to-fit contact hazard protection.
Odobrenja
UL + C-UL (listed)
Izjave
Declaration of conformity
PCF-declaration
Dokumentacija
Instructions
Quick guide
Safety instructions
RiLineX connection adaptor (1060 A)

RiLineX connection adaptor for 60 mm
busbar systems. The device has screw fastening
for simultaneous contact between the rail and conductor.
For voltages up to 1000 V AC and 1500 V DC.
IEC and UL approved.
Product information
Number of poles: 1
Busbar dimensions: 15/20/30 mm x 10 mm
Schienendicke: 10 mm
Rated current max.: 1060 A
Connection: max. 300 mm²
Cable outlet: oben/unten
Dimensions: 54 mm x 120 mm x 165 mm (WxHxD)
Manufacturer: Rittal GmbH & Co. KG
Type: 9361315