IT infrastructure

IT cooling

Climate control concepts from Rittal cover the full spectrum of applications, from cooling a single rack through to entire data centres. Safety and efficiency are our priorities.

IT cooling

LCP Rear Door CW

The LCP Rear Door CW is the perfect solution for dissipating heat from IT racks efficiently. Thanks to the modular concept consisting of a passive, active and water module, heat can be dissipated out of the server room directly from the rack, via the...

IT cooling

Liquid Cooling Package

LCP CW: Extremely high heat loads are dissipated from the IT racks via air/water heat exchangers. LCP DX: Ideal for cooling of small and medium-sized IT applications.

IT cooling

Liquid Cooling Units

Efficient cooling of VX IT racks and Micro Data Centers with no loss of space. Optimum support of IT-compatible, "front-to-back" air routing. High level of fail-safeness thanks to availability of single and redundant variant.

IT cooling

Small cooling units

Active and passive components for cooling individual IT racks.

IT cooling

IT room cooling

Reliable and energy-efficient room cooling for data centres with the highest level of precision and reliability. CyberAir 3PRO CW, CyberAir 3PRO DX and CyberAir Mini CW room cooling systems from the Stulz portfolio.

IT cooling

Chillers for IT cooling

Dependable cooling for IT applications such as LCP or air/water heat exchangers or for project-specific requirements.

IT cooling

Accessories for IT cooling

Matching accessories for Blue e+ cooling units, LCP CW and LCP DX applications.

IT cooling

Aisle containment

Door and roof components separate hot and cold air in the data centre. Such a separation is pivotal to increasing the efficiency of climate control technology. It may be used as a hot or cold aisle containment.

IT cooling

Roof-mounted cooling unit Blue e+ IT

The use of Blue e+ technology makes this bundle ideally suited to the requirements of energy-efficient cooling of IT racks. In combination with the IoT interfaces, it supports communication with various systems as well as monitoring and energy management.

IT cooling

Wall-mounted cooling unit Blue e+ IT

The use of Blue e+ technology makes this bundle ideally suited to the requirements of energy-efficient cooling of IT racks. In combination with the IoT interfaces, it supports communication with various systems as well as monitoring and energy management.

IT cooling

Roof-mounted cooling units for cooling IT equipment

Active climate control of individual enclosures for heat losses of up to 3 kW. Target temperature-controlled control of the server inlet temperature.

The different types of server climate control and their areas of application

From Liquid Cooling Packages and Liquid Cooling Units that use air/water heat exchangers to ensure optimum server rack climate control through to small cooling units that ventilate individual IT racks, chillers that are used for server cooling in IT applications and roof-mounted cooling units for active individual rack cooling – Rittal offers a comprehensive portfolio of products for your server racks.

Our range also includes door and ceiling elements for aisle containment as well as numerous accessories for your server rack climate control.

A variety of Rittal server rack cooling options are available, with a maximum cooling output of up to 53 kilowatts.

If you would like to find out which server rack climate control solution is the right one for your particular application, we’ll be happy to offer you advice and support when it comes to selecting the appropriate IT cooling system.

Get in touch with Rittal

FAQs about server rack climate control

Why do servers need to be cooled?

Servers need to be cooled because they generate a considerable amount of heat when operating. The heat produced by processors, hard drives and other electronic components can result in overheating if it is not dissipated. Overheating can impair the performance of hardware, shorten its service life and, in the worst-case scenario, lead to system failures or equipment damage. Cooling helps maintain the optimum operating temperature to ensure reliable performance and a long server service life.

How high can the temperature inside a server rack be allowed to get?

A server room should have a constant temperature of between 18 and a maximum of 27 °C. However, it should be noted that lower temperatures are often preferable in order to provide an additional safety margin and maximise the service life of components.

How cool does a server room need to be?

The temperature inside the server rack should be maintained at between 18 and 27 °C, with the optimum temperature ranging from 20 to 22 °C. This prevents servers from overheating and ensures stable running.

What are the benefits of server rack climate control?

Rittal climate control concepts for server cooling offer the following benefits:

  • Extended service life for equipment, thanks to protection from overheating
  • Increased reliability and reduced downtimes
  • Efficient cooling, directly at the heat sources
  • Enhanced performance of hardware under optimum conditions
  • Protection from contaminants in the air and from dust
  • Controlled humidity to prevent static electricity
  • Minimised operating costs, thanks to energy-efficient systems

To sum up, server rack climate control plays a key role in maintaining the stable, reliable operation of IT systems, protects investments in hardware and reduces operating costs on a long-term basis.

If you have any questions, we’ll be happy to help.

Get in touch with us now!

If we have sparked your interest in our range, you can explore our download centre to get an overview of all our products.

The world's most efficient climate control solutions

Blue e+ Chiller – Efficient cooling for industry, outdoor & IT

The Blue e+ chillers from Rittal provide powerful and energy-efficient solutions for demanding cooling applications in industrial manufacturing, outdoor applications such as battery energy storage systems (BESS), and IT infrastructure for small and...

RiMatrix Data Center

Discover our complete OT solution for a cooling capacity up to 400 kW per module. From planning to after-sales service – We empower IT.

Discover our complete OT solution for a cooling capacity up to 400 kW per module. From planning to after-sales service – We empower IT.

Sustainability that works

Minimising CO₂ emissions – the Blue e+ way

Discover the world's most efficient climate control solutions and smart service concepts to help reduce the carbon footprint of your machines and systems.

Decision making aid

How do I find the appropriate climate control solution?

Learn more about the different types of climate control and their advantages. We help you find the optimal solution for your requirements quickly and easily.