Product details
Connected upstream of the busbar. An overvoltage protection is available for each 3-phase infeed to the busbar. The overvoltage protection may also be retrofitted.
More on the product
Create PDF of this page+ Product description
Design: | Overvoltage protection type 3 |
---|---|
Product description: | Connected upstream of the busbar. An overvoltage protection is available for each 3-phase infeed to the busbar. The overvoltage protection may also be retrofitted. |
Connector (type): | Wago X-Com |
Phases per infeed: | 3~ |
Rated current (max.): | 16 A |
Note: | One adaptor is required for each infeed. |
Sockets: | Wago X-Com |
Packs of: | 1 pc(s). |
Weight/pack: | 0,82 kg |
Customs tariff number: | 85369001 |
EAN: | 4028177402621 |
ETIM 7.0: | EC000942 |
ECLASS 8.0: | 27130806 |
Product description: | DK PSM Overvoltage protection, Wago X-Com |
+ Approvals
Declerations: |
Declaration of conformity:
DE, EN
|
---|
+ Downloads / CAD
Documentation: |
Instructions:
DE, EN, FR
|
---|
+ Tender texts
Power System Module with overvoltage protection,
3-phase
Installation via plug & play
3-phase overvoltage protection
Overvoltage protection is available for every 3-phase
busbar supply. Overvoltage protection can also be
fitted as an upgrade. Integrated visual function
checks.
The pre-configured connection cable is used to supply
the power system module busbar. A 5-pole plug-in
connector strip is used to connect up the busbar.
Connection cable DK 7856.025 is needed for the supply.
Function
A green light will be lit if it is working correctly.
An overvoltage device failure is indicated by a red
light illuminating.
Requirement category
Overvoltage protection has been designed to meet Class
D requirements (different use with local sockets).
Intended use
The overvoltage socket strip has been designed for
overvoltage category ll protection as per DIN VDE 0110
Part 1.
Technical specifications:
3-phase voltage range: 110V - 400 V AC 50/60Hz
Max. current per supply 3 x 16 A
Type of cable: H07RN-F 5G2.5 mm² Temperature range:
+5°C - +45°C
Humidity range: 5% - 95% relative humidity,
non-condensing
Protection category IP 20
3-phase
Installation via plug & play
3-phase overvoltage protection
Overvoltage protection is available for every 3-phase
busbar supply. Overvoltage protection can also be
fitted as an upgrade. Integrated visual function
checks.
The pre-configured connection cable is used to supply
the power system module busbar. A 5-pole plug-in
connector strip is used to connect up the busbar.
Connection cable DK 7856.025 is needed for the supply.
Function
A green light will be lit if it is working correctly.
An overvoltage device failure is indicated by a red
light illuminating.
Requirement category
Overvoltage protection has been designed to meet Class
D requirements (different use with local sockets).
Intended use
The overvoltage socket strip has been designed for
overvoltage category ll protection as per DIN VDE 0110
Part 1.
Technical specifications:
3-phase voltage range: 110V - 400 V AC 50/60Hz
Max. current per supply 3 x 16 A
Type of cable: H07RN-F 5G2.5 mm² Temperature range:
+5°C - +45°C
Humidity range: 5% - 95% relative humidity,
non-condensing
Protection category IP 20