- Article number:
- SK 3311.491
- Design
- LCU DX 3 kW redundant
- Benefits
- Space-saving solution by installing the redundantly designed internal unit in the VX IT server enclosure or the Micro Data Center
- Maximum energy efficiency due to EC fan technology and IT-based control
- Control of the server inlet temperature
- The inverter-controlled compressor adapts the cooling output to the current heat loss inside the enclosure
- Absorbed thermal energy is emitted directly to the ambient air at the (inverter-controlled) external unit's location, without heating up the installation room
- Applications
- Cooling unit for VX IT server racks and for Micro Data Centers
- Function principle
- The redundant variants have two cooling circuits and controllers inside the internal unit, plus two inverter-regulated external units. The fault and operating hours changeover allows regular switching between the two external units, and ensures automatic changeover in the event of a malfunction or failure.
- The device supports front-to-back air routing typical of IT applications, and regulates the server inlet temperature to the set value
- Material
- Sheet steel, spray-finished
- Colour
- Internal unit: RAL 7035
External unit: white
- Supply includes
- Internal unit (evaporator coil)
2 external units (inverter-controlled)
482.6 mm (19") mounting trim panel with display and control components
Condensate hose
- Installation options in VX
- 482.6 mm (19") mounting angles, standard or dynamic, must be offset in the width by 50 mm off-centre
- The front distance between the 482.6 mm (19") mounting angles and the front edge of the VX frame must be at least 100 mm
- Two punched sections with mounting flanges are required for attachment on the inner mounting level
- Air baffle plates are required to separate the hot/cold zones within an enclosure
- A base/plinth is required to route the cable downwards
- Note
- Below the operating limit, fluctuations in the air inlet temperature are possible
- The electrical connection is made on the external unit. The internal unit is supplied by the external unit.
- A separate power supply may be needed, depending on the external unit
- IP protection category to IEC 60 529
- Internal unit IP 20
- External unit IP X4
- Modulation range
- 1 ‐ 3 kW
- Max. cooling output
- 3 kW
- Type of electrical connection
- Connection clamp
- Duty cycle
- 100 %
- Refrigerant/cooling medium
- Refrigerant: R410A
- To fit
- Enclosure type: VX IT
Width: = 800 mm
Height: ≥ 1,800 mm
Depth: ≥ 1,000 mm
- Internal unit dimensions
- Width: 105 mm
Height: 1,550 mm
Depth: 820 mm
- External unit dimensions
- Width: 810 mm
Height: 558 mm
Depth: 310 mm
- Rated operating voltage
- 230 V, 1~, 50 Hz
- Pre-fuse
- 16 A
- Rated current
- 7 A
- Packs of
- 1 pc(s).
- Net weight
- 129.2 kg
- Gross weight
- 136 kg
- Customs tariff number
- 84158200
- EAN
- 4028177709331
- ETIM 9
- EC000855
- ETIM 8
- EC000855
- ECLASS 8.0
- 27180704
- Product description
-
SK LCU DX split cooling unit 3 kW, refrigerant-based cooling of IT racks and Micro Data Centers, 2 x external units with inverter-controlled compressors, 1 x internal unit, redundant version