Liquid Cooling Package LCP Rack CW/CWG

Article no.: SK 3314.268

Cooling via high-performance compact impellers. The LCP draws in air from the side at the rear of the server enclosure and blows the cooled air back into the front part of the server enclosure from the side.

Article no.:
SK 3314.268
Version
Rack cooling
CW
Benefits
Maximum energy efficiency due to EC fan technology and IT-based control
Minimal pressure loss at the air end, which in turn minimizes the power consumption of the fans
Control of the server air inlet temperature or (optionally) according to differential pressure
Redundant temperature sensor integrated at the air end
Optimum adaptability due to dynamic, continuous control of the cold water volume flow
By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs
Cooling capacity tailored to requirements thanks to modular fan units (fans can be replaced without tools and during operation)
Fan modules configurable as n+1 redundancy.
Standard 3-phase connection for electrical redundancy
The UL variant includes a 1- or 2-phase fixed connection with additional cover as standard.
The separation of cooling and enclosure prevents water from entering the server enclosure
A maximum floor area of 0.36 m² for all cooling services
Improved heat recovery due to high water return temperatures when using the LCP CW glycol variants, for example in conjunction with a heat pump
Optimum access for maintenance and service from the front and the rear
Function principle
The LCP draws in the air at the sides at the rear of the server enclosures, cools it using high-performance compact impellers, and blows the cooled air back into the front part of the server enclosure at the sides
Material
Housing: Carbon steel
Front door: Aluminum, anodized/spray-finished
Carbon steel, spray finished
Surface finish
RAL 9005, fine structure matt
Color
Housing: RAL 7035
Front door: Vertical sections, silver colored and horizontal sections, RAL 9005
RAL 9005
Options
Fully integrated fire detection and extinguisher system
Automatic server enclosure door opening
Direct connection of an additional 16 CMC III sensors is possible
Racks in height 2200 mm, special colour
Condensate management kit including baffle separator plus temperature and humidity sensor
Display
Monitoring
Monitoring of all system-relevant parameters such as server air intake temperature, server waste air temperature, water inlet/return temperature, water flow, cooling output, fan speed, leakage.
Direct connection of the device via SNMP and via Ethernet (2 Ethernet interfaces, thus simplified cascading of up to 16 LCPs)
null
Integration in RiZone OT Suite (Extended measurement and management functions, values can be transferred and visualized)
Total cooling output/number of fan modules
53 kW/6
( 180,844 BTU/h )
Air throughput (unimpeded air flow)
At 60 Hz: 8,000 m³/h
( At 60 Hz: 4,708.6 cfm )
Number of fan modules in supplied state
6
Dimensions
Width: 300 mm
Height: 2,000 mm
Depth: 1,200 mm
( Width: 11.8 ˝
Height: 78.7 ˝
Depth: 47.2 ˝ )
Suitable for enclosure type
VX IT
TS IT
Installation in bayed enclosure suite
Flush
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Max. cooling output
53 kW
( 180,844 BTU/h )
Type of connection (electrical)
Fixed connection with cover
Duty cycle
100 %
Cooling medium
Water
EC fan
Yes
Fans may be exchanged with the system operational
Yes
Temperature control
Infinitely variable fan control
2-way control ball valve
Water connections
DN 40 (G 1½" external thread)
Permissible operating pressure (p. max.)
10 bar
( 145 PSI )
Water inlet temperature
15 °C
( 59 °F )
Protection category IP to EN 60 529
IP 20
Optimized condensate management even at low water flow temperatures
Yes
Options
Fully integrated fire detection and extinguisher system
Automatic server enclosure door opening
Direct connection of an additional 16 CMC III sensors is possible
Racks in height 2200 mm, special colour
Condensate management kit including baffle separator plus temperature and humidity sensor
Display
Packaging unit
1 pc(s).
Net weight
224 kg
Gross weight
237.5 kg
Customs tariff number
84186900
EAN
4028177977679
Product description
SK LCP rack CW, 53 kW, UL, WxHxD: 300x2000x1200 mm, RAL 9005, finely textured, matt
Approvals
UL + C-UL (listed)
Documentation
Additional information
Info sheet
Instructions
Data sheets
Visio Shapes
Software
MIB files
Software