RiLineX Bus-mounting fuse base

Article number: RX 9360.802

Bus-mounting fuse base for RiLineX and 60 mm busbar systems. For slow fuse D01 (with gauge ring) and D02 (E18). With optical LED fuse monitoring. For reliable fuse contacting, the device has fuse holders instead of screw caps which are lockable the open state and sealable in the closed state. A spring terminal block up to 16 mm² at angle of 45° allows easier conductor connection. The device is suitable for tool-free, snap-on mounting and features semi-automatic busbar adjustment for 5 and 10 mm.

Article number:
RX 9360.802
Benefits
Safe contacting of the fuse links (without screw caps)
Snap-on mounting and easy adjustment on busbar thickness 5/10 mm
Optical LED fuse monitoring
Voltage test through separate opening
Maintenance-free tension spring connection up to 16 mm²
Complete contact hazard protection without any additional accessories (such as screw caps)
Material
Polyamide (PA 6)
Fire protection corresponding to UL 94-V0
Color
RAL 35745
RAL 9005
Supply includes
4 bus-mounting fuse bases
12 reducers for D 01 fuses
Cable outlet
Bottom
Number of poles
3-pole
Suitable for busbar system
RiLineX
RiLine60
Dimensions
Width: 27 mm
Height: 263 mm
Depth: 123.5 mm
( Width: 1.06 ˝
Height: 10.4 ˝
Depth: 4.86 ˝ )
Connection of round conductors, fine wire with wire end ferrule
1.5 ‐ 16 mm²
Connection of round conductors, fine wire with wire end ferrule AWG
AWG 16 ‐ AWG 6
Connection of round conductors, multi-wire
1.5 ‐ 16 mm²
Connection of round conductors, multi-wire AWG
AWG 16 ‐ AWG 6
Suitable for busbars
Height: 5, 10 mm
( Height: 0.2, 0.39 ˝ )
Suitable for busbars
15 x 5/10 mm
20 x 5/10 mm
30 x 5/10 mm
Rated voltage
400 V AC
Overvoltage category
4
Contamination level
3
Standards
IEC 60 947-3
Rated insulation voltage
1,000 V
Power dissipation (max.)
5.5 W
( 19 BTU/h )
Protection category IP to IEC 60 529
IP 2XB
Operation humidity max
90 %
Operating temperature range
-5 °C...55 °C
( 23 °F...131 °F )
Storage temperature range
-25 °C...75 °C
( -13 °F...167 °F )
Ambient humidity (non-condensing)
10...90 %
Utilisation category
AC-21B (400 V/100 A)
Fuse inserts
D 02-E 18
Packaging unit
4 pc(s).
Net weight
1.432 kg
Gross weight
1.437 kg
Copper weight (kg per piece)
0.07
Customs tariff number
85369095
ETIM 9
EC001644
Product description
RX Bus-mounting fuse base 63 A, 3-pole, D02-E18, with LED, W: 27 mm
Declarations
Declaration of conformity
Documentation
Instructions
Quick guide
Safety instructions
Data sheets
General technical information