PDU metered plus

Model No. DK 7979.511

  Product Lifecycle  
New
  • PDU metered plus
    Product details

    High-end IT rack power distribution: Smart PDU with energy measurement per slot, i.e. output requirement for each individual consumer.

    Not available off the shelf, please contact your sales representative.

    + Product description

    Description: High-end power distribution in a compact design for IT network and server racks. With power measurement per individual outgoing slot.
    Benefits: For vertical mounting, it may be attached in the zero-U space of the Rittal VX IT or TS IT rack with no need for tools
    Colour coding of phases and fuse circuits (L1=pink, L2=black, L3=white)
    Tool-free divider kit for VX IT
    PDU self-supplied, no external power supply required
    Measurement accuracy ± 1% (kWh) to IEC 50430-1
    Integral real-time clock with battery buffering (max. 10 years, battery replaceable)
    Integral electromagnetic buzzer for acoustic alarms
    Adjustable limit values (warning/alarm) for current, voltage, output, individual settings for each output slot
    Power-saving design, minimal intrinsic power consumption
    Technical specifications: Display/controller unit in the PDU enclosure rotatable through 180° and replaceable
    Integral, fully-redundant power pack, power supply from all phases
    Error-tolerant PDU power supply redundant across all phases
    Voltage V, current A, frequency Hz
    Active power, active energy, apparent power, apparent energy
    Power factor (cosPhi) and phase angle
    Zero conductor current measurement/load imbalance detection
    Fuse monitoring for PDUs with integral fuse
    Bright TFT display, 128 x 128 pixels (RGB) with back-lighting and energy-saving mode to display output data and basic PDU configuration
    Position sensors for display rotation and correct PDU representation on the website
    Multi-colour LEDs (green/amber/red) to indicate switching states and limits per individual output slot
    Power LED to indicate voltage
    Measurement functions: Measurement per phase or infeed
    Plus measurement per output slot
    Powerful CPU (ARM Cortex A8)
    Digital input (floating contact)
    Additional alarm output/relay output (changeover contact)
    Material: Aluminium section, black anodised
    Slots: Plastic
    Protection category IP to IEC 60 529: IP 20
    Standards: EN 62368-1
    EN 61000-3
    EN 61000-4
    EN 61000-6
    EN 62053-21
    Directives: EMC Directive 2014/30/EU
    Low Voltage Directive 2014/35/EU
    Supply includes: Assembly parts
    Options: Type 3 overvoltage protection with interchangeable arresters while operational, with status monitoring, suitable for integration into PDU enclosure
    Residual current measurement (type B) per infeed/phase/fuse
    Monitoring of the optionally available overvoltage protection
    CMC III CAN bus sensors may be connected for ambient monitoring, max. 8 sensors
    Other enclosure colours are available
    Sockets: 10 
    To fit: Enclosure type: VX IT enclosure frame
    Enclosure type: VX IT 19" mounting angles
    Height: ≥ 1200 mm
    Height: ≥ 1800 mm
    Dimensions: Width: 44 mm
    Depth: 70 mm
    Length: 1095 mm
    Infeeds: Qty.: 1
    Phases per infeed: 1~
    Length of connection cable: 3 m
    Ambient conditions: Operating temperature: +5 °C...+50 °C
    Storage temperature: -20 °C...+70 °C
    Ambient humidity (non-condensing): 10 % - 95 %
    Type of electrical connection: CEE
    Rated current (max.): 16 A
    Output: 3,7 kW
    Interfaces: USB 2.0 port (USB-A) for mass configuration, firmware updates & data logging
    CAN bus interface (RJ 45) for a maximum of 8 ambient sensors
    Serial interface RS232 (RJ12) for LTE unit, scripting, CLI
    Use of own certificates/TLS 1.2
    E-mail forwarding in case of alarm (SMTP)
    User administration including rights management
    LDAP(S)/Radius/Active Directory connection
    Syslog server connection (max. 2 servers)
    Fully redundant monitoring via 2nd network
    Network protocol: TCP/IP v4 & v6, DHCP, DNS
    Network protocol: SNMP v1, v2c & v3, Modbus/TCP, OPC-UA
    Packs of: 1 pc(s).
    EAN: 4028177948303
    Customs tariff number: 85369095
    ETIM 7.0: EC000330
    ETIM 6.0: EC000330
    eCl@ss 8.0/8.1: 27142604
    eCl@ss 6.0/6.1: 27142604
    Product description: PDU metered+ 16A/1P CEE 10xCEE7/3 earthing-pin, DK PDU metered+, Compact basic power distributor, incl. energy measurement per output slot, with network interface and display

    + Approvals

    Certificates:
    EAC: 
    (RU)
    Declarations:
    Declaration of conformity: 
    (EN, DE)

    + Downloads

    Documentation:
    Brief instruction:  
    FR, EN, DE   PL   RU  
    Drivers/software:
    Software:  
    DE   EN   EN, DE  

    + Add accessories


     
     
     
     
     
     
     

     PDU metered plus

    Model No. DK 7979.511

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree