RiLineX connection adaptor

Obj. č.: RX 9361315

RiLineX connection adaptor for 60 mm busbar systems. The connection adaptor is single-pole and fits a double connection (round/sector-shaped conductor). The phase spacing is freely selectable. The unit is suitable for use with L1/L2/L3/N. The adaptor boasts an impressive compact design. Dismantling requires the use of tools. Conductors may be connected either from above or below. The connection clamps support full through-wiring. Mounted by simply snapping onto the RiLineX board. The adaptor is readily installed on RiLine60. It offers high levels of short-circuit protection and easy-to-fit contact hazard protection.

Obj. č.:
RX 9361315
Výhody
Mounting on the busbar system and cable connection with just one screw
Materiál
Polyamid (PA 6)
Ochrana proti požiaru zodpovedá UL 94
Farba
RAL 9005
Menovitý prúd (max.)
864 A
Menovitý prúd max.
1 060 A
Rated current of round conductor
1 060 A
Rated current of round conductor (UL)
980 A
Elektrické parametre UL (SCCR)
27,5 kA - 600 V, RMS, unprotected
100 kA - 600 V, circuit breaker max. 600 A, DIVQ/7
100 kA - 600 V, Fuse Class L max. 2000 A, JDDZ/7
Vývod vodičov
Top/bottom
Pre prípojnicové systémy s rozstupom
60 mm
Počet pólov
Single-pole
Vhodné pre prípojnicový systém
RiLineX
RiLine60
Rozmery
Šírka: 54,1 mm
Výška: 119,4 mm
Hĺbka: 163,4 mm
Pripojenie okrúhlych vodičov
95 ‐ 300 mm²
Vhodné pre prípojnice
15 x 10 mm
20 x 10 mm
30 x 10 mm
Rated voltage
1 000 V AC
1 500 V DC
600 V AC (UL)
600 V DC (UL)
Trieda prepätia
4
Stupeň znečistenia
3
Normy
IEC/EN 61439-1
UL 508
Menovité rázové napätie Uimp
12 kV
Rated insulation voltage Ui
1 000 V
Stratový výkon max.
105 W
Stupeň krytia IP podľa normy IEC 60 529
IP 2X
Maximum operating air humidity
90 %
Rozsah prevádzkových teplôt
-5 °C...55 °C
Rozsah skladovacích teplôt
-25 °C...75 °C
Vlhkosť vzduchu (nekondenzujúca)
10...90 %
Počet prípojok
2
Balenie
1 pc(s).
Netto hmotnosť
0,8 kg
Brutto hmotnosť
0,892 kg
PCF per pack (cradle-to-gate)
4,47
Číslo colnej sadzby
85369010
ETIM 9
EC001531
Popis výrobku
RiLineX connection adaptor for 60 mm busbar systems. The connection adaptor is single-pole and fits a double connection (round/sector-shaped conductor). The phase spacing is freely selectable. The unit is suitable for use with L1/L2/L3/N. The adaptor boasts an impressive compact design. Dismantling requires the use of tools. Conductors may be connected either from above or below. The connection clamps support full through-wiring. Mounted by simply snapping onto the RiLineX board. The adaptor is readily installed on RiLine60. It offers high levels of short-circuit protection and easy-to-fit contact hazard protection.
Certifikáty
UL + C-UL (listed)
Certifikáty
Declaration of conformity
PCF-declaration
Na stiahnutie
Quick guide
Safety instructions