TopTherm chillers 1 - 6 kW

Article number: SK 3334.600

TopTherm chillers in roof-mounted or stand-alone versions are flexible and compact. They offer centralized and efficient cooling of the cooling water and supply air/water heat exchangers and other devices. With nano-coated condenser as standard.

Article number:
SK 3334.600
Version
Compact, modular layout of the refrigeration components
Pump to convey the medium
Benefits
Precise temperature control, based on microprocessor technology
Collective fault signal with floating contact
One version for two frequencies = international compatibility
Color
RAL 7035
Supply includes
Condenser with hydrophobic RiNano coating
Complete unit ready for connection
Multilingual documentation including functional diagram and wiring plans
Protection category IP to EN 60 529
IP 44 (electrics)
Total cooling output Tw10 / Tu32
Cooling output Tw10 Tu32/50 Hz: 3.9 kW
Cooling output Tw10 Tu32/60 Hz: 4.7 kW
( Cooling output Tw10 Tu32/50 Hz: 13,307 BTU/h
Cooling output Tw10 Tu32/60 Hz: 16,037 BTU/h )
Total cooling output Tw18 / Tu32
Cooling output Tw18 Tu32/50 Hz: 4.5 kW
Cooling output Tw18 Tu32/60 Hz: 5.4 kW
( Cooling output Tw18 Tu32/50 Hz: 15,355 BTU/h
Cooling output Tw18 Tu32/60 Hz: 18,426 BTU/h )
Air throughput (unimpeded air flow)
At 50 Hz: 1,785 m³/h
At 60 Hz: 1,785 m³/h
( At 50 Hz: 1,050.6 cfm
At 60 Hz: 1,050.6 cfm )
Rated operating voltage
400 V, 3~, 50 Hz
460 V, 3~, 60 Hz
Dimensions
Width: 602 mm
Height: 676 mm
Depth: 645 mm
( Width: 23.7 ˝
Height: 26.6 ˝
Depth: 25.4 ˝ )
Temperature control
Microcontroller control (factory setting +20 °C)
Operating temperature range
10 °C...43 °C
( 50 °F...109 °F )
Operating temperature range of cooling medium
10 °C...30 °C
( 50 °F...86 °F )
Temperature hysteresis
± 2 K
Refrigerant/cooling medium
Refrigerant: R134a
Quantity: 1.5 kg
Global Warming Potential (GWP): 1,430
CO₂ equivalent (CO₂e): 2.15 t
( Refrigerant: R134a
Quantity: 3.3 lb. )
Rated power Pel
At 50 Hz: 2.88 kW
At 60 Hz: 3.24 kW
Rated current max.
At 50 Hz: 5.6 A
At 60 Hz: 6.15 A
Water circuit
Open
Water connections
G ½" internal thread
Number of cooling circuits
1
Tank
Material: Plastic PP
Volume: 30 l
Packaging unit
1 pc(s).
Weight/packaging unit
94 kg
( 207.2 lb. )
Customs tariff number
84186900
EAN
4028177351189
ETIM 7.0
EC002516
ECLASS 8.0
27180713
Product description
SK Chiller TopTherm, Stand alone, open, 15355/18426 BTU/h, 400-460 V, 3~, 50/60 Hz, WHD: 602 x 676 x 645 mm
Declarations
Declaration of conformity
Documentation
Additional information
Electrical wiring diagram
Fluid plan (P+ID)
Instructions
White Paper
Data sheets
Safety data sheet refrigerant
Technical details