RiLineX bus-mounting fuse base

Artículo No.: RX 9360.802

RiLineX bus-mounting fuse base for 60 mm busbar systems. For slow fuse D 01 (with gauge ring) and D 02 (E18). With optical LED fuse monitoring. For reliable fuse contacting, the device has fuse holders instead of screw caps which are lockable the open state and sealable in the closed state. A spring terminal block up to 16 mm² at an angle of 45° allows easier conductor connection. The device is suitable for tool-free, snap-on mounting and features semi-automatic busbar adjustment for 5 and 10 mm.

Artículo No.:
RX 9360.802
Ventajas
Reliable contacting of fuse inserts (without screw caps)
Snap-on mounting and simple adjustment for busbar thickness (5/10 mm)
Optical LED fuse monitoring
Voltage test through separate opening
Maintenance-free tension spring connection up to 16 mm²
Complete contact hazard protection without any additional accessories (such as screw caps)
Material
Poliamida (PA 6)
Protección frente a fuego según UL 94-V0
Color
RAL 35745
RAL 9005
Unidad de envase
4 bus-mounting fuse bases
12 reducers for D 01 fuses
Salida de cables
abajo
N° de polos
3 polos
Adecuado para sistema de barras colectoras
RiLineX
RiLine60
Dimensiones
Anchura: 27 mm
Altura: 263 mm
Profundidad: 123,5 mm
Conexión de conductores cilíndricos, hilos finos con casquillos terminales
1,5 ‐ 16 mm²
Conexión de conductores cilíndricos, hilos finos con casquillos terminales AWG
AWG 16 ‐ AWG 6
Conexión de conductores cilíndricos, multifilares
1,5 ‐ 16 mm²
Conexión de conductores cilíndricos, multifilares AWG
AWG 16 ‐ AWG 6
Adecuado para barras colectoras
Altura: 5, 10 mm
Adecuado para barras colectoras
15 x 5/10 mm
20 x 5/10 mm
30 x 5/10 mm
Tensión nominal
400 V AC
Categoría de sobretensión
4
Grado de suciedad
3
Normas
IEC/DIN EN 60 947-3
Rated insulation voltage
1,000 V
Power dissipation (max.)
5.5 W
Grado de protección IP según IEC 60 529
IP 2XB
Operation humidity max
90 %
Campo de temperatura de servicio
-5 °C...55 °C
Campo de temperatura de almacenaje
-25 °C...75 °C
Humedad del aire (sin condensación)
10...90 %
Utilisation category
AC-21B (400 V/100 A)
Fusibles
D 02-E 18
Unidad de embalaje
4 pza(s).
Peso neto
1.432 kg
Peso bruto
1.437 kg
Contenido de cobre (kg / pza.)
0.07
Código arancelario
85369095
ETIM 9
EC001644
Descripción producto
RiLineX bus-mounting fuse base for 60 mm busbar systems. For slow fuse D 01 (with gauge ring) and D 02 (E18). With optical LED fuse monitoring. For reliable fuse contacting, the device has fuse holders instead of screw caps which are lockable the open state and sealable in the closed state. A spring terminal block up to 16 mm² at an angle of 45° allows easier conductor connection. The device is suitable for tool-free, snap-on mounting and features semi-automatic busbar adjustment for 5 and 10 mm.