RiLineX baying set for board

Articolul nr.: RX 9360000

RiLineX baying connector set for the complete board, for use with 550 A and 800 A. Comprising a busbar connector and contact hazard protection cover. For simple baying of boards between two bayed VX enclosures, no drilling required.

Articolul nr.:
RX 9360000
Benefits
Time savings thanks to fully digital product data
Reduced assembly time thanks to pre-assembled complete board
Tested short-circuit resistance up to 65 kA
Suitable for applications up to 1000 V AC and up to 1500 V DC
Tested and certified to IEC and UL
Simple extension and baying
Material
Upper part: Sheet steel, zinc-plated
Contact plate: E-Cu, tin-plated
Front cover: Polyamide (PA 6)
Fire protection corresponding to UL 94
Colour
RAL 35745
Supply includes
3 busbar connectors
1 front cover
1 insulating plate
IP protection category to IEC 60 529
IP 2XB
Standards
IEC 61 439-1/-2
UL 508
Rated current max.
780 A
Rated current (UL)
780 A
Electrical ratings UL (SCCR)
52.5 kA - 600 V, RMS, unprotected
100 kA - 600 V, Fuse Class L max. 1600 A, JDDZ/7
100 kA - 600 V, circuit breaker max. 600 A, DIVQ/7
100 kA - 480 V, circuit breaker max. 800 A, DIVQ/7
65 kA - 600 V, circuit breaker max. 800 A, DIVQ/7
Rated impulse withstand voltage Uimp
12 kV
Rated voltage
1.000 V AC
1.500 V DC
600 V AC (UL)
600 V DC (UL)
Rated insulation voltage Ui
1.000 V AC
1.500 V DC
Rated impulse withstand current
103 kA
115,5 kA
Rated short-term withstand current/t
45 kA/200 ms
52.5 kA/500 ms
Overvoltage category
4
Contamination level
3
Number of poles
3-pole
To fit Model No.
9360004
9360008
9360024
9360028
9360064
9360068
9360084
9360088
Fundamental frequency
50...60 Hz
Ambient humidity (non-condensing)
10...90 %
To fit busbars
30 x 5/10 mm
Operating temperature range
-5 °C...55 °C
Dimensions
Width: 154 mm
Height: 240 mm
Depth: 77 mm
Packs of
1 pc(s).
Net weight
1,88 kg
Gross weight
1,924 kg
Copper weight (kg per piece)
0,297
Customs tariff number
85369010
EAN
4028177997431
ETIM 9
EC002270
Product description
RiLineX baying connector set for the complete board, for use with 550 A and 800 A. Comprising a busbar connector and contact hazard protection cover. For simple, no-drill baying of boards between two bayed enclosures. Baying connectors are included with the supply.
Aprobări
UL + C-UL (listed)
Declarații
Declaration of conformity
Documentație
Quick guide
Safety instructions
Foi de date
General technical information
RiLineX baying set for board

Baying connector set for the complete board, for use
with 550 A and 800 A. Comprising a busbar connector and
contact hazard protection cover. For simple baying
of boards between two bayed enclosures,
no drilling required.
Tested short-circuit resistance up to 65 kA.
IEC and UL approved.
Product information
Number of poles: 3
Busbar dimensions: 30 mm x 5/10 mm
Rated current max.: 550/800 A
Dimensions: 154 mm x 240 mm x 77 mm (WxHxD)
Manufacturer: Rittal GmbH & Co. KG
Type: 9360000