- Article no.:
- RX 9361315
- Benefits
- Mounting on the busbar system and cable connection with just one screw
- Material
- Polyamide (PA 6)
Fire behavior corresponding to UL 94
- Color
- RAL 9005
- Rated current (guideline value, IEC)
- 864 A
- Max. rated current of round conductor (IEC)
- 1,060 A
- Max. rated current of round conductors (UL)
- 980 A
- Note
- The specified rated current as a guideline value is based on the recommended maximum operating current for single-wire cables with an admissible conductor temperature of 70 °C to IEC 61439-1, Table H.1 when laid horizontally in free air, at an ambient temperature of 55 °C.
- The specified max. rated current (IEC) describes the recommended max. operating current of the terminal connection with a temperature rise limit of 70K to IEC 61439-1 (Table 6) for conductors laid in free air with clearance. Please note the maximum admissible insulation temperature.
- Electrical UL ratings (SCCR)
- 27.5 kA - 600 V, RMS, unprotected
- 100 kA - 600 V, circuit breaker max. 600 A, DIVQ/7
- 100 kA - 600 V, fuse class L max. 2000 A, JDDZ/7
- Cable outlet
- Top/bottom
- For bar systems with center-to-center spacing
- 60 mm
- Number of poles
- 1-pole
- Suitable for busbar system
- RiLineX
- RiLine60
- Dimensions
- Width: 54.1 mm
Height: 119.4 mm
Depth: 163.4 mm( Width: 2.13 ˝
Height: 4.7 ˝
Depth: 6.43 ˝ )
- Connection of round conductors
- 95 ‐ 300 mm²
- Suitable for busbars
- 15 x 10 mm
- 20 x 10 mm
- 30 x 10 mm
- Rated voltage
- 1,000 V AC
1,500 V DC
600 V AC (UL)
600 V DC (UL)
- Contamination level
- 3
- Standards
- IEC/EN 61439-1
- UL 508
- Rated impulse withstand voltage UImp
- 12 kV
- Rated insulation voltage Ui
- 1,000 V
- Power loss max.
- 105 W( 358 BTU/h )
- Protection category IP to IEC 60 529
- IP 2X
- Maximum operating air humidity
- 90 %
- Operating temperature range
- -5 °C...55 °C( 23 °F...131 °F )
- Storage temperature range
- -25 °C...75 °C( -13 °F...167 °F )
- Ambient humidity (non-condensing)
- 10...90 %
- Number of connections
- 2
- Fire load
- 5.947 MJ/m²
- Packaging unit
- 1 pc(s).
- Net weight
- 0.8 kg
- Gross weight
- 0.892 kg
- PCF/VE (cradle-to-gate)
- 4.47
- Customs tariff number
- 85369010
- ETIM 9
- EC001531
- Product description
-
RiLineX connection adapter for 60 mm busbar systems. The connection adapter is single-pole and fits a double connection (round/sector-shaped conductor). The phase spacing is freely selectable. The unit is suitable for use with L1/L2/L3/N. The adapter boasts an impressive compact design. Dismantling requires the use of tools. Conductors may be connected either from above or below. The terminals support full through-wiring. Mounted by simply snapping onto the RiLineX board. The adapter is readily installed on RiLine60. It offers high levels of short-circuit protection and easy-to-fit contact hazard protection.