Find out more about the operation and benefits of our products for the various types of climate control – from air cooling and cooling units to liquid cooling and enclosure heating.
Air cooling
Operation:
- Heat loss to be dissipated up to 2,900 W at ∆T = 10 K
- The heat inside the enclosure is dissipated into the surroundings via a forced airflow (air exchange)
- Air routing inside the enclosure may be at both the extracting and discharging end
Benefits:
- Highly versatile as a result of different design variants – standard, EMC and EC technology
- Tool-free work (installing on enclosure, making electrical connections, quickly replacing filter mats)
- Lower energy costs due to shorter running time in the case of fan-and-filter units with efficient EC motor
- Integrated interface for easy monitoring and control of fan speed/operation in the case of EC fans
Operation:
- Heat loss to be dissipated up to 3,100 W at ∆T = 10 K
- The heat inside the enclosure is dissipated into the surroundings via a forced airflow (air exchange)
Benefits:
- Highly versatile as a result of different design variants – standard and EC technology
- Simple assembly and maintenance (innovative clamp fixing, plug terminal ensures easy electrical connection, filter mats can be replaced quickly)
- High protection category of IP 55 as standard
- Excellent efficiency and integrated interface for speed regulation and fan monitoring in the case of EC fans
Operation:
- Heat loss to be dissipated up to 900 W at ∆T = 10 K
- Unlike fans, the air/air heat exchanger consists of two closed circuits
- Instead of external air flowing through the enclosure, external and internal air flow through the heat exchanger fins according to the cross-flow principle
- The heat in the internal air is absorbed by the external air without any direct contact, which means a high protection category can be achieved, as the contaminated external air does not come into direct contact with the air inside the enclosure
Benefits:
- Reduced maintenance thanks to separate control of internal and external fans
- Easy cleaning thanks to a removable heat exchanger module
- Longer maintenance intervals, which reduces servicing costs
Cooling units
Funcionalidade:
- Perda de energia a ser dissipada em até 80 W para L35/L35
- O aparelho de refrigeração Peltier funciona de acordo com o princípio termoelétrico, segundo o qual um fluxo de corrente elétrica causa uma diferença de temperatura entre dois condutores metálicos sob certas condições
Vantagens:
- Ecologicamente correto, uma vez que gases e refrigerantes não são necessários
- Operação praticamente livre de manutenção
- Alta precisão de controle
- Montagem em qualquer posição (exceto montagem em telhado)
Funcionalidade:
- Perda de energia a ser dissipada em até 5800 W para L35/L35
- Por meio de um agente refrigerante (refrigerante R134a) o ar é resfriado em um circuito interno e externo separado no invólucro e o calor é dissipado no ambiente
- Uma vez que nenhum ar de fora alcança o invólucro, um alto grau de proteção é atingido
Vantagens:
- Pode ser implementado de maneira flexível por conta de variantes diferentes de instalação em chapa de aço (padrão), aço inoxidável e de uso externo
- Uma média de 75% de economia de energia por conta da tecnologica híbrida inovadora
- Vida útil mais longa dos componentes por conta do resfriamento adaptado (regulamento PID)
- Operação prática por tela sensível ao toque e interfaces inteligentes
- Montagem fácil graças aos recortes de montagem uniformes e auxiliares de montagem
Operation:
- Heat loss to be dissipated up to 3,950 W at L35/L35
- Using a cooling medium (refrigerant R134a), the air in the enclosure is cooled in a separate internal and external circuit, and the heat is dissipated into the surroundings
- Because external air does not enter the enclosure, a high protection category is achieved
Benefits:
- Highly versatile and can be used all over the world thanks to different design variants in sheet steel (standard), stainless steel, NEMA 4x and NEMA 3R/4
- Minimal maintenance as a result of nano-coating and integrated condensate evaporation
- Longer service life for components in the enclosure and for cooling units thanks to the use of efficient components such as fans and compressors
- Energy efficiency thanks to Eco-mode control – the evaporator fan is deactivated in line with requirements based on the internal enclosure temperature
Operation:
- Heat loss to be dissipated up to 2,500 W at L35/L35
- Using a cooling medium (refrigerant R134a), the air in the enclosure is cooled in a separate internal and external circuit, and the heat is dissipated into the surroundings
- Because external air does not enter the enclosure, a high protection category is achieved
Benefits:
- Highly versatile, as all cooling modules can be individually combined with any climate control door
- Easy retrofitting – the existing door can be replaced without any machining and while the system is operational
- Energy efficiency thanks to Eco-mode control – the evaporator fan is deactivated in line with requirements based on the internal enclosure temperature
Operation:
- Heat loss to be dissipated up to 1,300 W at L35/L35
- Combination of an enclosure and a cooling unit
- Using a cooling medium (refrigerant R134a), the air in the enclosure is cooled in a separate internal and external circuit, and the heat is dissipated into the surroundings
- Because external air does not enter the enclosure, a high protection category is achieved
Benefits:
- The perfect symbiosis of the VX25 baying enclosure system and Blue e+ cooling unit reduces the amount of planning work required
- The cooling unit can be easily pulled out to the front for easy maintenance
- No assembly work required – the cooling unit, door-operated switch and connection cabling are installed ready to connect
Liquid cooling
Funcionalidade:
- Perda de energia a ser dissipada em até 7000 W para L35/W10 e 500 l/h
- O circuito interno e externo são separados, assim, um alto grau de proteção é atingido
- O agente refrigerante nestes dispositivos é água, via de regra
- Um circuito fechado de água abastece os dispositivos com água refrigerada
- O rearrefecimento pode se dar (de forma centralizada) por meio de um chiller
Vantagens:
- Pode ser implementado de maneira flexível por conta de variantes diferentes de instalação: Peças condutoras de água feitas de aço inoxidável (1.4571) ou de cobre/latão (Cu/CuZn), "Hygienic Design"
- Opções de ligação de água convenientes e flexíveis
- Todos os dispositivos com controle Comfort são equipados com controle Eco-Mode para uma variante eficiente que economiza energia: O ventilador é desligado conforme necessário, dependendo da temperatura dentro do painel elétrico
Funcionalidade:
- Perda de energia a ser dissipada em até 9500 W para L35/W10 e 2000 l/h
- O circuito interno e externo são separados, assim, um alto grau de proteção é atingido
- O agente refrigerante nestes dispositivos é água, via de regra
- Um circuito fechado de água abastece os dispositivos com água refrigerada
- O rearrefecimento pode se dar (de forma centralizada) por meio de um chiller
Vantagens:
- Opções flexíveis de conexão de água na parte superior ou inferior do dispositivo
- Possibilidade de instalação flexível, uma vez que a saída de ar é possível em ambos os lados com 5 kW cada ou em um lado com 10 kW
- Todos os dispositivos com controle Comfort são equipados com controle Eco-Mode para uma variante eficiente que economiza energia: O ventilador é desligado conforme necessário, dependendo da temperatura dentro do painel elétrico
Operation:
- Heat loss to be dissipated up to 5,500 W at Tw18/Tu35
- A chiller is a product that uses a liquid medium (water, oil, etc.) to remove heat from a consumer
- This liquid can be circulated by a heat exchanger to cool devices or another process flow (such as air or process water)
Benefits:
- High energy efficiency and reduction of carbon footprint by up to 70% thanks to innovative DC inverter technology and lower coolant use
- Highly versatile thanks to a wide temperature range of -5 °C to +50 °C
- Extremely reliable operation thanks to integrated safety functions
- Easy monitoring using remote monitoring via the IoT interface
Operation:
- Heat loss to be dissipated up to 25,000 W at Tw18/Tu32
- A chiller is a product that uses a liquid medium (water, oil, etc.) to remove heat from a consumer
- This liquid can be circulated by a heat exchanger to cool devices or another process flow (such as air or process water)
Benefits:
- Reduced quantity of refrigerant thanks to micro-channel technology
- Touch display for easy and convenient user guidance
- Extremely reliable operation thanks to integrated safety functions
- Pre-configured options reduce delivery times
Operation:
- Heat loss to be dissipated up to 25,000 W at Tw18/Tu35
- A chiller is a product that uses a liquid medium (water, oil, etc.) to remove heat from a consumer
- This liquid can be circulated by a heat exchanger to cool devices or another process flow (such as air or process water)
Benefits:
- Highly reliable thanks to icing protection
- One version for two frequencies = international compatibility
- Reduced quantity of refrigerant thanks to micro-channel technology
- Extremely reliable operation thanks to integrated safety functions
Enclosure heater
Operation:
- The PTC elements used in all Rittal enclosure heaters automatically regulate their resistance and thus their thermal output based on the temperature
Benefits:
- Self-regulating PTC technology for optimum regulation of thermal output
- Protection against condensation in the enclosure
- Consistent heat distribution to prevent heat pockets
- Easy assembly thanks to quick-connecting terminal for tool-free electrical connection (spring clamp terminal)