RiLineX connection adaptor

Št. artikla: RX 9360210

RiLineX connection adaptor for 60 mm busbar systems. The adaptor boasts an impressive compact design and simple conductor connection. Dismantling requires the use of tools. Conductors may be connected either from above or below. The connection clamps support through-wiring. Mounted by simply snapping onto the RiLineX board. The supply leads and adaptors are screw-fastened onto the board together. The connection adaptor features a high current-carrying capacity plus high levels of short-circuit protection and universal contact hazard protection that adapts to the relevant wire gauge. The device has a screw fastening, and is suitable for bar widths of between 5 and 10 mm.

Št. artikla:
RX 9360210
Prednosti
Mounting on the busbar system and cable connection with just one screw
Material
Poliamid (PA 6)
Protipožarna zaščita v skladu z UL 94
Barva
RAL 9005
Rated current (guideline value, IEC)
171 A
Max. rated current of round conductor (IEC)
320 A
Max. rated current of round conductors (UL)
280 A
Opomba
The specified rated current as a guideline value is based on the recommended maximum operating current for single-wire cables with an admissible conductor temperature of 70 °C to IEC 61439-1, Table H.1 when laid horizontally in free air, at an ambient temperature of 55 °C.
The specified max. rated current (IEC) describes the recommended max. operating current of the terminal connection with a temperature rise limit of 70K to IEC 61439-1 (Table 6) for conductors laid in free air with clearance. Please note the maximum admissible insulation temperature.
Električne nazivne vrednosti UL (SCCR)
10 kA - 600 V, RMS
100 kA - 600 V, circuit breaker max. 250 A, DIVQ/7
100 kA - 600 V, Fuse Class J max. 200 A, JDDZ/7
Kabelska vtičnica
Top/bottom
Za sisteme palic z razmakom med središči
60 mm
Število polov
3-pole
Za namestitev sistema zbiralnih sponk
RiLineX
RiLine60
Mere
Širina: 63,2 mm
Višina: 239,4 mm
Globina: 79,2 mm
Priklop okroglih vodnikov
2,5 ‐ 70 mm²
Za namestitev zbiralnih sponk
12 x 5/10 mm
15 x 5/10 mm
20 x 5/10 mm
30 x 5/10 mm
Rated voltage
800 V AC
800 V DC
600 V AC (UL)
600 V DC (UL)
Stopnja kontaminacije
3
Standardi
IEC/EN 61439-1
UL 508
Nazivna impulzna vzdržna napetost Uimp
8 kV
Rated insulation voltage Ui
800 V
Izguba toplote maks.
14 W
IP razred zaščite po IEC 60 529
IP 2X
Maximum operating air humidity
90 %
Delovno temperaturno območje
-5 °C...55 °C
Temperaturno območje shranjevanja
-25 °C...75 °C
Vlažnost okolice (brez kondenzacije)
10...90 %
Fire load
6,963 MJ/m²
Paketi
4 pc(s).
Neto teža
1,776 kg
Bruto teža
1,925 kg
PCF na paket (od zibelke do vrat)
9,86
Carinska tarifna številka
85369010
EAN
4028177997257
ETIM 9
EC001531
Opis izdelka
RiLineX connection adaptor for 60 mm busbar systems. The adaptor boasts an impressive compact design and simple conductor connection. Dismantling requires the use of tools. Conductors may be connected either from above or below. The connection clamps support through-wiring. Mounted by simply snapping onto the RiLineX board. The supply leads and adaptors are screw-fastened onto the board together. The connection adaptor features a high current-carrying capacity plus high levels of short-circuit protection and universal contact hazard protection that adapts to the relevant wire gauge. The device has a screw fastening, and is suitable for bar widths of between 5 and 10 mm.
Odobritve
UL + C-UL (listed)
Izjave
Declaration of conformity
PCF-declaration
Dokumentacija
Instructions
Quick guide
Safety instructions