Service for Direct Liquid Cooling

Reliable operation for high-end AI and HPC environments

DLC Service

Service for Direct Liquid Cooling

Direct Liquid Cooling is what makes the high power densities of cutting-edge AI and HPC data centres possible. But as liquid cooling systems become ever more sophisticated, the demands on their maintenance and availability become ever tougher. A reliable service concept makes all the difference when trying to keep everything running smoothly with Direct Liquid Cooling. To help you achieve maximum performance with maximum availability, Rittal DLC Service ensures your IT Infrastructure can run on a reliable, efficient and plannable basis.

We keep IT running.

The Direct Liquid Cooling service concept

As a manufacturer, we know every detail of the DLC infrastructure and offer you a service concept that covers the entire life cycle – saving time, lowering costs and safeguarding availability.

Installation and commissioning

Safe and fast go-live through professional commissioning by experts

Liquid analysis

Optimum coolant quality for maximum reliability and consistent cooling output

Maintenance and hot-swap service

Repair and replacement of critical components without downtime

Spare parts

Reduced downtime thanks to immediate access to mission-critical components

DLC services in brief

Installation and commissioning

Getting a DLC system up and running requires specialist know-how. Highly skilled Rittal service engineers will check the hydraulics, ensure the system is leak-tight, rinse the pipelines and calibrate the control parameters. That means you benefit from:

  • A short ramp-up phase and reduced configuration bugs and leakage risks
  • Operational reliability and full cooling capacity from day one, thanks to a residue-free system

Preventive maintenance and service agreements

Regular maintenance is the cornerstone of reliable DLC operation. Rittal recommends that, in the first year, maintenance is carried out during commissioning and after six months. From the second year of operation, maintenance is recommended every six months.

  • CDU maintenance including visual check, technical inspection, functional testing, cleaning or replacement of the filter, and liquid analysis
  • Safeguarded, maximum cooling output, thanks to the regular sampling, monitoring and documentation of coolant
  • Reduced risk of unanticipated repair costs
  • Plannable IT budget thanks to bundling of services in a single contract
     

Hot-swap service

Thanks to our hot-swap function, critical components such as pump units, control modules and filters can be replaced without having to shut down or interrupt the system – with complete and traceable documentation included.

  • No downtime caused by repairs and maintenance
  • Maximum operational reliability and system availability

Liquid analysis

The performance and reliability of a DLC system stands and falls by the quality and chemical composition of its coolant. That’s why the mix of glycol and deionised water circulating in the CDU In-Row needs to be very strictly monitored.

  • Regular testing of the pH value, glycol concentration, turbidity and conductivity
  • Prevention of corrosion, sedimentation and creeping performance losses
  • Protection of the system and maintenance of maximum cooling output

Spare parts

Choose from a range of predefined DLC spare parts packages depending on the criticality of each component – from pumps, filters and valves to seals, sensors and control units.

  • Minimised downtimes, thanks to immediate availability of spare parts
  • Faster restoration when servicing is required
  • Bespoke customisation as required

Fully qualified DLC service from a single partner

From commissioning and maintenance to technical support, Rittal Direct Liquid Cooling (DLC) Service supports data centre operators in achieving safe, efficient and high-availability operation of their liquid cooling infrastructure.

FAQ – service for direct liquid cooling

What kind of service do I need for direct liquid cooling if I want to guarantee a stable IT infrastructure?

How can I avoid downtime if I need to carry out repairs?

Why is it important that a filter in the CDU In-Row can be replaced during operation and how does that work?

Why is liquid analysis an important aspect of CDU In-Row maintenance?

Other links

AI cooling

Direct Liquid Cooling

Artificial intelligence and high-performance computing (HPC) pose new challenges for data centers. Increasing computing power and high-power densities resulting from AI workloads, GPUs and processors generate massive heat...

360° Service portfolio

Rittal 360° service – there for you anytime and anywhere

Sustainability and energy efficiency are among the biggest challenges facing organisations today. At the same time, uptime of critical equipment still needs to be guaranteed in production processes at all times. Downtime and performance losses cost...