Cooling units, Thermoelectric Cooler

Cooling units keep the enclosure internal temperature at a constant level, which is independent of the ambient temperature. The air routing meets individual requirements. Two separate circuits prevent the ingress of dust into the enclosure.

F-Gas Regulation (EU): Future-proof your cooling system

With the F-Gas Regulation (EU) 2024/573, the European Union is tightening the rules for refrigerants. The focus is on the GWP (Global Warming Potential), which rates the climate impact of a refrigerant. From 2027, a GWP limit of 150 will apply to many cooling units and chillers up to 12 kW. From that date onwards, new units exceeding this limit will, by law, no longer be permitted to be placed on the market. Anyone investing today in machinery, plant or enclosure cooling should take these requirements into account at an early stage and opt for future-proof solutions.

Cooling units and chillers with a low GWP

To comply with GWP limits, Rittal is converting its cooling units and chiller platforms to the future-proof refrigerant R-1234yf. With a GWP of only 0.5, these solutions comfortably meet the requirements of the F-Gas Regulation and offer long-term planning certainty for industry and mechanical engineering.

Available Rittal Products:

Available from Q1 2027: 

  • Blue e+ S cooling units, stainless steel, 0.3 – 1.0 kW
  • Blue e roof-mounted cooling units, 0.6 – 4.0 kW
  • Blue e horizontal wall-mounted cooling unit, 0.3 kW
     

Exceptions to the GWP limit

  • If safety requirements at the installation site do not permit the use of R-1234yf, the F-Gas Regulation allows for an exemption permitting the use of refrigerants with a GWP of up to 750.
  • For this purpose, Rittal continues to offer product variants with R-513A (GWP = 631).

TUEV Rheinland confirms the safety of R-1234yf refrigerant in Rittal cooling units

View TUEV report

Tried and tested and safe: R-1234yf

R-1234yf is classified as A2L according to ASHRAE 34 / ISO 817: low toxicity and flame-retardant. Due to its high lower flammability limit of approximately 6.2 vol%, flammable mixtures are only possible under highly unlikely conditions. The refrigerant has also been in use for many years in millions of vehicle air conditioning systems and is recognized worldwide as proven and safe.

All Rittal cooling units with R-1234yf:

  • comply with EN/IEC 60335-2-40 and UL 60335-2-40
  • remain below the permissible refrigerant fill levels
  • require no additional safety measures such as leak sensors or forced ventilation

Tests by the Federal Institute for Materials Research and Testing (BAM) confirm: There is no fire hazard under real operating conditions.

F-Gas compliance at a glance – Compliance Check in RiTherm

RiTherm automatically checks whether the selected cooling unit complies with current and future requirements for the reduction of fluorinated greenhouse gases for both the European and US markets.

The F-Gas check in RiTherm provides you with the following information:

  • GWP of the refrigerant used
  • Regulatory assessment in accordance with the F-Gas Regulation (EU) and the US AIM Act
  • Clear recommendations for action if a refrigerant is no longer permitted
     

We are there for you!

Got any questions? Please message us. We'll be delighted to answer all your questions relating to the F-Gas Regulation and refrigerant switchover.

FAQ on the F-Gas Regulation

The F-Gas Regulation gradually reduces the use of climate-damaging refrigerants with a high GWP. The aim is to reduce greenhouse gas emissions and accelerate the transition to sustainable refrigerants.

The requirements of the F-Gas Regulation apply exclusively to new equipment placed on the market; they do not apply to the operation or maintenance of existing systems. Existing systems may continue to be operated and maintained as normal until 2032 using the refrigerants R134a, R410a and R-513A (GWP > 150). After that date, a ban on servicing and maintenance will come into force for systems using refrigerants with a GWP exceeding 750.

Yes, this is important for manufacturers, importers and exporters. Anyone who imports or exports refrigerants or equipment containing F-Gases must register on the European Union’s F-Gas Portal. This ensures that trade flows can be fully traced. This requirement does not apply to end users.

The GWP (Global Warming Potential) indicates the extent to which a refrigerant contributes to global warming, compared with carbon dioxide (CO₂). A GWP of 150 means that, over a 100-year period, the refrigerant contributes 150 times more to global warming than the same amount of CO₂.

The refrigerant R-1234yf has been used by automotive manufacturers for over a decade in millions of vehicles as the standard refrigerant in vehicle air-conditioning systems. It has established itself as a reliable and safe solution when properly specified, installed and maintained.