    Ideal for cooling of small and medium-sized IT applications.

    + Also required

    + Product description

    Design: DX/FC
    Benefits: Maximum energy efficiency due to EC fan technology and IT-based control
    Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans
    Temperature monitoring and control
    With redundant temperature sensor integrated at the air end as standard
    Thanks to the speed-regulated compressor, the cooling output is ideally adapted to actual requirements
    Specific maintenance of the LCP DX due to separation of cooling and server racks
    Using LCP DX/FC variants in combination with indirect free cooling helps to save operating costs
    Applications: Ideal for IT cooling of small and medium-sized locations
    One or two racks can be cooled separately
    Function principle: The LCP is designed for siting within a bayed enclosure suite. Hot air is drawn in from the aisle at the rear of the device, cooled by the high-capacity compact impellers, and blown back into the room or cold aisle after cooling.
    The LCP DX/FC variants include both a refrigerant and a water/glycol heat exchanger. There is an additional free cooler integrated into the external condenser.
    Absorbed thermal energy is emitted to the ambient air at the external condenser location, without heating up the installation room
    Material: Sheet steel, spray-finished
    Colour: RAL 7035
    Options: Humidifier
    Dehumidification and reheater
    Condensate drain pump
    Low-temperature/high-temperature condenser (-40 °C/+53 °C)
    Design: Suite cooling
    Monitoring: Direct connection of the unit via SNMP over Ethernet
    Integration into RiZone
    Modulation range: 8 ‐ 35 kW
    Total cooling output/Number of fan modules: 35 kW/3
    Air throughput (unimpeded air flow): At 50 Hz: 9,900 m³/h
    Dimensions: Width: 600 mm
    Height: 2,000 mm
    Depth: 1,200 mm
    To fit enclosure type: VX IT
    Installation in bayed enclosure suite: Flush
    Rated operating voltage: 380 V - 480 V, 3~, 50 Hz/60 Hz
    Rated current max.: At 50 Hz: 31.6 A
    Max. cooling output: 35 kW
    Type of electrical connection: Connection clamp
    Duty cycle: 100 %
    Cooling medium: Refrigerant
    EC fan: yes
    SNMP card: yes
    Fans may be exchanged with the system operational: yes
    Temperature control: Linear fan control
    Inverter-controlled compressor
    Pre-fuse: Miniature circuit-breaker/fuse: 50 A
    Operating temperature range: 5 °C...35 °C
    Noise level: At 50 Hz: 69 dB(A)
    Protection category to IEC 60 529: IP 20
    Packs of: 1 pc(s).
    Weight/pack: 398 kg
    Customs tariff number: 84195080
    EAN: 4028177953994
    ETIM 8: EC002515
    ETIM 7.0: EC002515
    ECLASS 8.0: 27180712
    Product description: LCP Inline DX / FC, 35 kW, flush, RAL 7035, WHD: 600 x 2000 x 1200 mm, 380 – 480 V/3~/50 – 60 Hz

    + Approvals

    Declerations:
    Declaration of conformity: 
    DE, EN

    + Downloads / CAD

    Data Sheets:
    Graphics: 
    DE EN
    Technical Data sheet: 
    DE EN
    Documentation:
    Instructions: 
    DE EN

    + Tender texts

    LCP Inline DX/FC 35kW, 3313.480
    WHD (mm) 600x2000x1200mm

    IT-optimised design, providing ideal support for "front-to-back" air
    routing for the 482.6 mm (19") installations.

    The unit is a combination of direct evaporation (DX) and air/water heat
    exchanger (FC) system for usage of free cooling.
    Because of that, a DX heat exchanger is installed after the FC one, in
    order to exploit as much as possible free-cooling capacity before
    activating the DX system.
    Due to measurement values, the internal controller is able to control
    between efficient FC-, Mix- or DX operation.

    The unit is able to guarantee a cooling output of up to 35 kW with
    standard server enclosure dimensions, the lowest possible weight, and
    comprehensive possibilities for monitoring.
    The LCP Inline DX/FC is mounted on the side of the rack.
    The warm server air is drawn in through a perforated rear door and the
    cooled air is blown back via a perforated door in front of the
    perforated doors of the server rack and is thus made available to the
    482.6 mm (19") equipment once more.
    The LCP Inline DX/FC is closed up to the server rack at the front and
    rear and there forms a flush joint with the rack.

    The unit is equipped with three EC fans, for maximum efficiency and
    minimum power consumption.
    The flow characteristics of the heat exchanger are optimised for the
    lowest possible pressure losses on the air side. This minimises the
    energy consumption of the fans.

    An integrated inverter with corresponding controller serves to regulate
    the speed of the installed compressor.
    An inverter pump is controlling the necessary flow in FC- or Mix-mode.
    The presence of inverter compressor, inverter pump and a continuous
    control of the external unit fans permit to achieve a stepless
    adaptation of the cooling output, also in partial-load operation and in
    all 3 working modes of the system, thus granting high precision of the
    airflow temperature to the servers.
    Moreover they guarantee elevated energy consumption reduction with
    consequent reduction in operating costs.
    Furthermore, being the 2 systems (DX and FC) fully independent, in case
    of failure of one of the 2, the other can partially or fully cover the
    cooling capacity required, thanks to the advanced software control

    Alongside the compressor, the refrigerant circuit of the LCP Inline
    DX/FC comprises a liquid receiver, electronic expansion valve,
    refrigerant sight glass, optimised heat exchanger, high and low-pressure
    sensors, Schrader valves, filter dryer, non-return valve,
    high/low-pressure switch and shut-off devices.
    The refrigerant connections and the electrical power connection to the
    unit can be realised from above or below.

    The liquid circuit (FC) is including the heat exchanger, expansion
    vessel, safety valve, filling device and inverter pump.
    The LCP Inline DX/FC and the server rack remain separate from each
    other. This simplifies assembly and service work and excludes the need
    for unwanted access to the server rack for maintenance purposes.
    Maintenance and service for all relevant components can be realised
    quickly and simply from front or rear, thanks to the optimised layout.
    The fans can be exchanged quickly and at any time, even while the system
    is operational (hot swapping).
    The fans are installed in the cold air section, which increases their
    service life.

    Condensate management is integrated into the unit. Any condensate is
    collected in a collecting tray in the base and from there discharged to
    the outside via a hose.

    Thanks to the integrated controller, the LCP Inline DX/FC operates fully
    autonomously.
    The setpoint is the server intake air temperature, which is
    automatically held constant at the set value.
    Two sensors are present in each case for detection of the cold and warm
    air temperatures, providing for the appropriate redundancy.

    Monitoring and alarm management for all physical parameters is realised
    via SNMP and Ethernet.
    SNMP interface is directly integrated.

    A display with operating keys is integrated on the front of the unit to
    display and set the physical parameters.

    The external hybrid condenser is needed to operate the LCP Inline DX/FC
    and has to be ordered separately.
    Inside the hybrid condenser, the refrigerant condenser and additional
    free cooling heat exchanger are included: after the installation, the DX
    system has to be filled in with refrigerant R410A while the CW system
    with water with the right percentage of glycol
    Wall- or roof mounting are possible

    Installation and commissioning on site, laying of the refrigerant pipes,
    and evacuation and filling of the system with refrigerant are not
    included in the scope of supply and must be realised by correspondingly
    qualified persons.

    Technical specifications:
    Useful cooling output:,,
    35 kW at 35 °C ambient temperature at place of installation of the
    condenser
    Installed fans: 3
    Air throughput: max.9000 m³/h
    Intake temperature, set: 22 °C
    Connection, liquid side: 16 mm
    Connection, gas discharge side: 16 mm
    Connection, liquid inlet (water/glycol): 1 diameter external thread
    Connection, liquid outlet (water/glycol): 1 diameter external thread
    Power supply:,,400 V, 3~, N, PE, 50/ 60 Hz (voltage range 380-480 V)
    Prefuse: 50A
    Max. connected load: 14,60kW
    Refrigerant: R410A
    Connection length, max.: 60 m
    Max. delivery height, inverter pump: 3bar
    Height difference (condenser higher/lower), max: 20/3 m
    Dimensions (WxHxD): 600x2000x1200mm
    Colour: RAL 7035
    Integrated SNMP card for network connection

    Option on application:
    Humidifier
    Dehumidification + heater
    Air filter (G3) with monitoring
    Condensate pump

    Needed accessories:
    3311.380,,
    Air cooled hybrid condenser for 3313.480 (-20°C to +45°C)

     Liquid Cooling Package LCP Inline DX, LCP Inline DX/FC

    Model No.

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree

    Close