Options for level E modular safe

Innovations 2013

Level E modular safe T1 1060 1060 T2 B1 H1 H2 B2 T3 U 42 47 42 47 External dimensions mm Width (B1) 1100 1115 1115 1115 Height (H1) 2210 2405 2205 2405 Depth (T1) 1200 1353 1553 1553 Internal dimensions mm Width (B1) 920 900 900 900 Height (H1) 2030 2200 2000 2200 Depth (T1) 1000 1060 1260 1260 Model No. (Safe is configured on a project-specific basis) 7999.009 7999.009 7999.009 7999.009 Empty weight excluding cooling unit and excluding rack approx. kg 660 700 730 800 Accessories TS IT Rack with air baffle plates W 600 x H 2000 x D 1000 7995.045 – – – W 600 x H 2200 x D 1000 – 7995.046 – – W 800 x H 2000 x D 1000 7995.047 – – – W 800 x H 2200 x D 1000 – 7995.048 – – Fire alarm and extinguisher system DET-AC/EFD Plus see Catalogue 33, page 510 CMC monitoring system see Catalogue 33, from page 768 PSM – Power System Module busbar see Catalogue 33, from page 382 PDU – Power Distribution Unit see Innovations 2012, from page 91 Split cooling solutions see IT-News 2013, from page 63 LCP – Liquid Cooling Package, rack depth 1000 mm see IT-News 2013, from page 43 62 Rittal Innovations 2013 O Applications: ◾ A high level of protection against potential physical threats for IT ◾ Targeted configuration components transform the safe into a complete, compact data centre Benefits: ◾ As well as facilitating installation in poorly accessible sites, the modular design also makes it possible to retrospectively enclose existing IT structures. ◾ Extendibility, dismantling and re-assembly mean targeted, future-safe investments. ◾ System-tested security and a high level of protection Protection standards: – Fire protection – fire resistance class F 90 to DIN 4102 Part 2 – Compliance with limit values ΔT < 50 K, relative humidity 85% for 30 minutes – Burglar resistance WK II, III and IV, tool attack analogous to DIN V ENV 1630/1999-04/ WK II – Protection category IP 56 to IEC 60 529 – Smoke protection based on DIN 18 095-2: 1991-03 The tests were performed as system tests and confirmed with test certificates. Material: – Sheet steel, coated Colour: – Enclosure and service door: RAL 7035 – Operator door: RAL 9005 Supply includes: – Security safe with operator door and service door – Cable entry in both side elements – Both doors with key lock Optional: – Choice of door hinges – Bifold doors – Different cable entry systems – Cable entry additionally in the top or base unit – Different lock variants – Supporting structure Technical details: Available on the Internet. Standard protection from: Fire Extinguishing water Vandalism Unauthorised ac Corrosive gases cess Dust Theft/burglary


Innovations 2013
To see the actual publication please follow the link above