PDU managed

Model No. DK 7979.404

  Product Lifecycle  
New
  • PDU managed
  • PDU managed
    Product details

    High-end IT rack power distribution with energy measurement and monitoring functions for each individual output slot. Input with CEE connector (16 A/32 A) with C13 and C19 outputs.

    Not available off the shelf, please contact your sales representative.

    + Product description

    Design: Izvedba 19"
    Description: High-end power distribution in a compact design for IT network and server racks. Depending on the design, they come with an extensive range of management functions for energy measurement and monitoring.
    Benefits: For vertical mounting, it may be attached in the zero-U space of the Rittal VX IT or TS IT rack with no need for tools
    Colour coding of phases and fuse circuits (L1=pink, L2=black, L3=white)
    Tool-free divider kit for VX IT
    PDU self-supplied, no external power supply required
    Measurement accuracy ± 1% (kWh) to IEC 50430-1
    Programmable startup behaviour following voltage recovery (on/off/last status)
    Programmable switching behaviour (time/programmable logic)
    Integral real-time clock with battery buffering (max. 10 years, battery replaceable)
    Integral electromagnetic buzzer for acoustic alarms
    Adjustable limit values (warning/alarm) for current, voltage, output, individual settings for each output slot
    Technical specifications: Display/controller unit in the PDU enclosure rotatable through 180° and replaceable
    Integral, fully-redundant power pack, power supply from all phases
    Error-tolerant PDU power supply redundant across all phases
    Voltage V, current A, frequency Hz
    Active power, active energy, apparent power, apparent energy
    Power factor (cosPhi) and phase angle
    Zero conductor current measurement/load imbalance detection
    Fuse monitoring for PDUs with integral fuse
    Bright TFT display, 128 x 128 pixels (RGB) with back-lighting and energy-saving mode to display output data and basic PDU configuration
    Position sensors for display rotation and correct PDU representation on the website
    Multi-colour LEDs (green/amber/red) to indicate switching states and limits per individual output slot
    Power LED to indicate voltage
    Power-saving design, minimal intrinsic power consumption
    Measurement functions: Emergency power supply to PDU web server via PoE, sequential disconnection of the outputs
    Switching function per output slot
    Avoids overload peaks: Sequential activation of the outputs following voltage recovery
    Relay states are saved even in the event of a power failure
    Bistable relays: Low current consumption and high switching capacity, also suitable for higher starting currents up to max. 300 A
    Grouping: Joint switching of multiple outputs
    Measurement per phase or infeed
    Plus measurement per output slot
    Powerful CPU (ARM Cortex A8)
    Digital input (floating contact)
    Additional alarm output/relay output (changeover contact)
    Material: Aluminium section, black anodised
    Slots: Plastic
    Protection category IP to IEC 60 529: IP 20
    Standards: EN 62368-1
    EN 61000-3
    EN 61000-4
    EN 61000-6
    EN 62053-21
    Directives: EMC Directive 2014/30/EU
    Low Voltage Directive 2014/35/EU
    Supply includes: Assembly parts
    Options: Type 3 overvoltage protection with interchangeable arresters while operational, with status monitoring, suitable for integration into PDU enclosure
    Residual current measurement (type B) per infeed/phase/fuse
    Monitoring of the optionally available overvoltage protection
    CMC III CAN bus sensors may be connected for ambient monitoring, max. 8 sensors
    Other enclosure colours are available
    Variant: Measurement and monitoring functions per output slot, switched
    Sockets: 4  x C 13 
    2  x C 19 
    To fit: Enclosure type: VX IT enclosure frame
    Enclosure type: VX IT 19" mounting angles
    Height: ≥ 800 mm
    Height: ≥ 800 mm
    Dimensions: Height: 44 mm
    Depth: 144 mm
    Length: 450 mm
    Infeeds: Qty.: 1
    Phases per infeed: 1~
    Length of connection cable: 3 m
    Ambient conditions: Operating temperature: +5 °C...+50 °C
    Storage temperature: -20 °C...+70 °C
    Ambient humidity (non-condensing): 10 % - 95 %
    Circuit-breaker 16 A (qty.): 2
    Type of electrical connection: CEE
    Rated current (max.): 32 A
    Output: 7,4 kW
    Interfaces: Fully redundant Ethernet interface 10/100/1000 Mbit/s (2x RJ45, 1x with PoE)
    USB 2.0 port (USB-A) for mass configuration, firmware updates & data logging
    CAN bus interface (RJ 45) for a maximum of 8 ambient sensors
    Serial interface RS232 (RJ12) for LTE unit, scripting, CLI
    Use of own certificates/TLS 1.2
    E-mail forwarding in case of alarm (SMTP)
    User administration including rights management
    LDAP(S)/Radius/Active Directory connection
    Syslog server connection (max. 2 servers)
    Fully redundant monitoring via 2nd network
    Network protocol: TCP/IP v4 & v6, DHCP, DNS
    Network protocol: SNMP v1, v2c & v3, Modbus/TCP, OPC-UA
    Packs of: 1 pc(s).
    EAN: 4028177948068
    Customs tariff number: 85369095
    ETIM 7.0: EC000330
    ETIM 6.0: EC000330
    eCl@ss 8.0/8.1: 27142604
    eCl@ss 6.0/6.1: 27142604
    Product description: PDU managed 32A/1P CEE 4xC13+2xC19, DK PDU managed, High-end power distributor incl. extensive measurement,, switching and monitoring functions of each output slot, with network interface and display

    + Approvals

    Declarations:
    Declaration of conformity: 
    (EN, DE)

    + Downloads

    Documentation:
    Brief instruction:  
    FR, EN, DE   PL   RU  
    Drivers/software:
    Software:  
    DE   EN   EN, DE  

    + Add accessories


     
     
     
     
     
     
     

     PDU managed

    Model No. DK 7979.404

    Close
    +
    [X] Close

    Required 

    $nbsp;

    Product data (ZIP)

    Rittal does not assume any liability for the topicality of the data downloaded locally on your device.

     I agree